Pool heating energy calculator: how much heat does the water need?

Compare the heat needed for a chosen temperature rise with an assumed heating performance.

Your situation

Water and heating

Illustrative. Use 1 for ideal direct electric heat, or an appropriate heat-pump COP for the conditions.

Calculated from your figures

58.2 kWh of heat

Electricity at entered COP
29.1 kWh

What this means

This ideal water-heating estimate excludes ongoing heat losses and does not establish heating time.

How this was calculated

Based on the figures you entered.

  • The model assumes uniform water temperature and approximate water properties.
  • Evaporation, weather, covers, pipes, ongoing losses and heating time are excluded.

Method pool-heating-v1

The working

The maths, step by step

The figures match the displayed result and are rounded for display.

heat (kWh)=volume (m3)×1000×4.19×temperature rise (∘C)3600\text{heat (kWh)} = \frac{\text{volume (m}^3\text{)} \times 1000 \times 4.19 \times \text{temperature rise (}^\circ\text{C)}}{3600}
10×1000×4.19×5/3600≈58.19 kWh10 \times 1000 \times 4.19 \times 5 / 3600 \approx 58.19\ \text{kWh}

The estimate uses 1,000 kg per m³ and 4.19 kJ per kg per °C for water. Electricity is heat divided by the entered COP of 2; heat loss is excluded.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

The heat stored in the water

Enter the water volume and the temperature rise you want to explore. The tool estimates sensible heat using approximate water density and specific heat capacity, assuming the water reaches one uniform temperature.

This is the energy stored in the water for that rise. It is not the total energy a pool will need over a season.

Electricity depends on the heater

The coefficient of performance, or COP, is heat delivered divided by electricity used. An ideal direct electric heater is represented by a COP of one; a heat pump may have a different COP depending on its operating conditions.

The starting COP is illustrative. Use a value appropriate to the equipment and conditions you want to compare, rather than treating a single figure as a guarantee.

Real pools lose heat

Evaporation, wind, air temperature, ground contact, pipework and a pool cover can affect heat loss. Those losses are excluded, so this ideal estimate can be lower than the energy needed in practice.

The tool does not predict heating time, solar contribution or ongoing bills. Equipment size and operating conditions need a separate assessment.

Before you rely on this

Compare the heat needed for a chosen temperature rise with an assumed heating performance.

  • The model assumes uniform water temperature and approximate water properties.
  • Evaporation, weather, covers, pipes, ongoing losses and heating time are excluded.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does this include evaporation and pool heat loss?

No. It estimates heat stored in water for a temperature rise and excludes ongoing losses and weather.

What is the heating COP?

COP is heat delivered divided by electricity used. It depends on the heater and operating conditions.

Does this calculate how long the pool will take to warm?

No. Heating power and changing heat losses are not modelled, so the calculation is an energy estimate rather than a heating-time forecast.

Does this estimate how much solar power heats the pool?

No. It gives an ideal heat and electricity comparison without modelling solar generation or load timing.