What solar array might cover an off-grid daily load?

Compare a daily energy requirement with an entered solar resource and performance assumption.

Your situation

Daily energy and solar resource

Add the energy your loads use on the design day.

Illustrative only. Use a location- and season-specific design value, especially for winter.

Include the losses between the panel rating and energy delivered to the loads. Do not count the same loss twice.

Calculated from your figures

2.5 kW array

What this means

This balances the entered daily load against an assumed solar resource and performance factor. It is not a reliability guarantee.

How this was calculated

Based on the figures you entered.

  • Sun hours must be appropriate to the location, season and design period.
  • A daily energy balance does not guarantee reliability in poor weather or size the battery and inverter.

Method off-grid-array-v1

The working

The maths, step by step

The figures match the displayed result and are rounded for display.

array capacity (kW)=daily load (kWh)equivalent sun hours×performance fraction\text{array capacity (kW)} = \frac{\text{daily load (kWh)}}{\text{equivalent sun hours} \times \text{performance fraction}}
4÷(2×80/100)≈2.5 kW4 \div (2 \times 80/100) \approx 2.5\ \text{kW}

The entered sun hours and performance factor describe an illustrative design day, not a guarantee of supply.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Start with a design day

Enter the daily electricity demand you want the solar system to cover. Equivalent sun hours express the energy received as hours at a reference irradiance; they are not simply the number of hours between sunrise and sunset.

Choose a value for the actual location, panel orientation and season you are designing for. A yearly average can hide long periods of poor winter generation.

Allow for the energy path

The performance factor accounts for losses between panel nameplate capacity and the energy delivered to the loads. Include the losses relevant to your setup and avoid counting the same loss in both the load and performance factor.

The tool divides daily load by equivalent sun hours and the performance fraction. The result is a daily energy balance at the assumptions entered.

Plan beyond the average

Cloudy sequences, shading, snow and seasonal demand can leave a system short even if an average day balances. Battery capacity, charging rates, inverter power and reserve generation are separate decisions.

A qualified system designer should assess the full site and equipment. This illustration does not establish electrical compatibility or reliable year-round supply.

Before you rely on this

Compare a daily energy requirement with an entered solar resource and performance assumption.

  • Sun hours must be appropriate to the location, season and design period.
  • A daily energy balance does not guarantee reliability in poor weather or size the battery and inverter.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Are equivalent sun hours the same as daylight hours?

No. They express the received solar energy as equivalent hours at a reference irradiance, and depend on location, weather and the array plane.

Can an annual average guarantee winter supply?

No. Winter and prolonged cloudy periods may yield less than the average. Choose an appropriate design period and assess reserve supply.

Does this size the battery or inverter?

No. It only balances daily energy under the entered assumptions. Storage, power limits, charging and protection require separate assessment.

What belongs in the performance factor?

Use a factor for losses between the array rating and the energy delivered to the load. The appropriate value depends on the equipment and energy path.