How much battery capacity might an off-grid load need?

Explore the energy capacity needed for an entered daily load and time without replenishment.

Your situation

Daily energy and battery

Add the energy your loads use on the design day.

Use the usable depth of discharge appropriate to your battery and reserve.

Do not include this loss again in daily load.

Calculated from your figures

11.11 kWh nominal capacity

At the entered nominal voltage
463 Ah

What this means

This is an energy-only estimate; battery power, charging and prolonged poor weather need separate assessment.

How this was calculated

Based on the figures you entered.

  • The daily load, days without charge, usable fraction and discharge efficiency are entered assumptions.
  • This is not an electrical design, a power or surge check, or a guarantee of autonomy.

Method off-grid-battery-v1

The working

The maths, step by step

The figures match the displayed result and are rounded for display.

nominal capacity (kWh)=daily load×autonomy daysusable fraction×discharge efficiency\text{nominal capacity (kWh)} = \frac{\text{daily load} \times \text{autonomy days}}{\text{usable fraction} \times \text{discharge efficiency}}
4×2÷(80/100×90/100)≈11.11 kWh4 \times 2 \div (80/100 \times 90/100) \approx 11.11\ \text{kWh}

At 24 V, the displayed amp-hours are nominal capacity in kWh multiplied by 1,000 and divided by nominal voltage.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Build up your daily load

List the appliances you intend to run, their power and the hours each runs on a typical design day. Their energy adds up in kWh. Include loads that may be easy to miss, such as standby consumption, and avoid counting the same conversion loss twice.

Days of autonomy is the period you want the battery to supply that load without replenishment. A larger assumed period increases the energy capacity required, but it does not guarantee that charging will recover the battery afterwards.

Nominal and usable capacity

Nominal capacity is not necessarily all available to the load. Enter the usable share appropriate to the battery and reserve, then enter discharge efficiency separately. The calculation divides required load energy by both fractions.

The amp-hour figure is derived from the entered nominal bank voltage. Battery specifications can depend on discharge rate and temperature, and a nominal-voltage conversion is an approximation.

Energy is only one part of the design

A battery with enough kWh may still be unable to supply an appliance's running power or startup surge. Inverter limits, protection, wiring, charging, weather, battery chemistry and reserve supplies need separate consideration.

Use the result to discuss your assumptions with a qualified designer. It is not a guarantee of supply through an outage or a complete off-grid system specification.

Before you rely on this

Explore the energy capacity needed for an entered daily load and time without replenishment.

  • The daily load, days without charge, usable fraction and discharge efficiency are entered assumptions.
  • This is not an electrical design, a power or surge check, or a guarantee of autonomy.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

What are days of autonomy?

They are the entered period for which the battery is expected to supply the stated load without replenishment. This calculation assumes the same load each day.

Why is nominal capacity larger than the load energy?

Only the entered share of nominal capacity is used, and the entered discharge efficiency accounts for energy lost on the way to the load.

Does the battery capacity establish the inverter size?

No. Energy capacity in kWh and power in kW answer different questions. Running and starting loads need a separate power assessment.

Is the amp-hour result a battery recommendation?

No. It is a nominal-voltage conversion. Real capacity depends on battery specification, temperature, discharge rate and the system design.