Will your battery keep the lights on in a power cut?
Usually not, unless it was specified to. What backup actually requires and what it costs.

Explore this decision
How long could your battery keep things running?
Start with the things you need: lights, fridge and Wi-Fi. See how energy capacity and power limits answer two different questions.
Use your equipment's ratings. The example appliances are editable illustrative loads.
Explore this decision
How much battery capacity might an off-grid load need?
Explore the energy capacity needed for an entered daily load and time without replenishment.
The daily load, days without charge, usable fraction and discharge efficiency are entered assumptions.
Most home batteries do not keep the lights on during a power cut. People are routinely surprised by this, having reasonably assumed that a large battery attached to the house would do exactly that.
Backup is possible. It requires specific equipment and a specific installation, it costs more, and whether it is worth buying comes down to two questions you can answer honestly in a minute.
Why a standard installation shuts down
When the grid fails, a grid-connected inverter must disconnect. This is a safety requirement built into the G98/G99 connection rules every domestic system is installed under, not a limitation of the battery.
The reason is anti-islanding. If your system kept exporting into a dead network, it could energise cables that engineers believe are dead. So inverters are required to detect grid loss and stop.
A standard battery installation follows that rule, and when the grid drops, the whole system stops, battery included, however full it is. The battery is not broken and the installer did not cut a corner; the system is doing what its connection agreement requires.
What backup actually requires
Three things beyond a standard installation.
An inverter capable of forming a grid. Normally the inverter follows the grid’s voltage and frequency. In backup it has to create them. Not every hybrid inverter can, and those that can are more expensive.
A changeover arrangement. Something that physically disconnects your house from the network before the inverter energises it, so you cannot back-feed. This is a contactor or transfer switch, wired in at installation, and it is the piece that satisfies the anti-islanding rule while your lights stay on. Tesla’s warranty document lists a Backup Gateway as a separate part for exactly this job.
A separated circuit, usually. Many systems back up a subset of circuits rather than the whole house, because the inverter’s backup output is limited. That means a second consumer unit, or a split board, with the essential circuits moved onto it.
That third point is what makes retrofitting backup awkward. Deciding afterwards which circuits are essential means rewiring, which is why the question belongs in the original specification, alongside the sizing decision.
One more detail worth reading: some battery warranties define permitted operating modes and treat backup differently in their throughput terms, Tesla’s warranty document structures its cover by application, so check what your warranty says the battery is allowed to spend its cycles doing.
Automatic failover, emergency switches and uninterrupted power
Ask the installer to name the backup equipment and describe what you must do when the grid fails. An emergency isolator switches equipment off. It is not an automatic transfer system and does not make an ordinary installation provide backup.
An automatic changeover arrangement transfers supported circuits to the backup supply without you operating a switch. A manual changeover needs someone to operate it. An EPS output is an emergency power supply from the inverter; the circuits connected to it, its output limit and the installed changeover arrangement determine what it can actually power.
GivEnergy’s EPS guide describes dedicated backup circuits, manual whole-property changeover and automatic whole-property changeover as different installation options. It also describes a delay before EPS energises. Automatic switching therefore does not itself promise an uninterrupted supply: ask whether your router, computer or other equipment will restart, and check the exact system’s published transfer behaviour.
Have the installer specify the arrangement and demonstrate it at handover. The presence of a battery, a hybrid inverter or an emergency switch alone does not establish automatic backup.
What the cited documents actually say about backup
The warranty evidence below is separate from the EPS installation guide. Check both the exact product’s permitted operating modes and the backup arrangement included in the installation quote.
| Document | What it states about backup | Source | Checked |
|---|---|---|---|
| Tesla Powerwall warranty (Powerwall 2 and 3), European region, UK table | Backup is a named application, covered at 80% energy retention at ten years with unlimited cycles, alongside solar self-consumption and time-based control; a Backup Gateway is listed as a covered part | tesla.com | 2026-10-20 |
| Tesla Powerwall warranty, Limitation on Use | “Not intended for use as a primary or backup power source for life-support systems, other medical equipment, or any other use where product failure could lead to injury” | tesla.com | 2026-10-20 |
| Energy Networks Association, Connect my generation | G98 and G99 are the connection routes every domestic system is installed under; a grid-tied inverter must stop exporting when the grid fails | energynetworks.org | 2026-10-19 |
| GivEnergy warranty and product pages | Could not be checked: the FAQ page redirected to a placeholder and the datasheet blocked automated download on the date shown, so nothing is claimed here about its backup terms | givenergy.co.uk | 2026-10-19 |
The second row is the one to take seriously if backup is for medical equipment: the manufacturer whose document is clearest about backup is also explicit that it is not for that purpose.
Whole-house or essential circuits
Essential circuits is the common approach: lighting, sockets in key rooms, the fridge, the router, the boiler’s controls. Cheaper, and it means the battery lasts far longer because it is not running everything.
Whole house needs an inverter with enough continuous output to cover whatever might be switched on. Possible, more expensive, and it drains the battery quickly if you are not careful.
Decide before installation, because the wiring differs.
What it will not run, with the arithmetic
Even in backup, high-power loads are usually out of reach. An electric shower at 8 or 9 kilowatts, an oven at 2 or more, an immersion heater at 3, or a 7 kilowatt EV charger will individually or together exceed most domestic inverters’ backup output, which commonly sits in the 3 to 5 kilowatt range.
Heating is the one people most often get wrong. A gas boiler needs only its electronics and pump, perhaps 100 watts, which is easily backed up. Electric heating is not.
How long it lasts
Divide usable battery capacity by the load you are actually running.
An essential-circuits load, fridge, router, some lighting, a boiler’s electronics, runs around 300 watts. A battery with 10 usable kilowatt hours carries that for about 33 hours, which outlasts almost any UK interruption. Run a 3 kilowatt whole-house evening instead and the same battery is empty in a little over three hours. At the end of a warranty floor of 80%, the same unit holds 8 and the essential load runs for about 27 hours; a 13.5 kWh unit at that floor holds 10.8, about 36 hours.
If the cut happens during daylight and your solar is configured to work in backup, the array can recharge the battery, which changes the picture entirely. Ask whether your proposed system does that: some backup configurations keep the solar running, and some do not.
What the quote will say
Battery backup: keep your home running during power cuts.
Six words, and every one of them needs a number. Which circuits, at what continuous output, for how long at that output, from what state of charge, and does the array recharge it in daylight? A quote that includes backup will have a gateway or changeover device on the parts list and a backup output rating on the inverter; one that does not has promised the feature without pricing it, and the feature will arrive as an extra or not at all.
Whether it is worth it
Ask two questions.
How often does your supply actually fail? Most UK households experience very few and very short interruptions. If yours is one of them, backup is buying reassurance rather than avoiding a real cost, and the premium should be judged as reassurance: the battery’s financial case stands or falls on cycling economics either way, and backup adds cost without adding a single cycled unit.
What does a cut actually cost you? A freezer full of food, a home business, medical equipment, a rural property at the end of a long feeder with a history of outages. In those cases it is a genuine requirement, the premium is insurance against a real and recurring loss, and the essential-circuits design above is usually the right shape for it. For medical equipment, read the Limitation on Use row above and plan for a dedicated solution rather than relying on the house battery.
For most households it is a comfort feature, and it is worth pricing as one rather than assuming it comes free with the battery.
Questions people ask
Why does my battery turn off when the power goes out?
Because the inverter is required to. Every grid-connected system is installed under the G98 or G99 rules, which require a grid-tied inverter to detect the loss of the grid and stop, so that it cannot energise a network engineers believe is dead. A battery with no changeover device and no grid-forming inverter follows that rule and shuts down with everything else, full or not. It is the correct behaviour, not a fault.
Can backup be added to an existing battery?
Sometimes, at a cost that is usually higher than specifying it at the start. It needs a grid-forming inverter, which may mean replacing the one you have, a changeover device, and the essential circuits moved onto a separate board, which is rewiring. Ask the installer for the parts list and the backup output rating before assuming the existing unit can do it.
Does backup use up the warranty?
It depends on the document. Tesla’s UK terms treat backup as a covered application with unlimited cycles, the same as solar self-consumption, so the occasional cut costs nothing on that warranty; other manufacturers’ terms may put backup under a throughput clause. Read the operating mode clauses, and remember that a power cut is rare enough that its cycles are a rounding error beside daily use.
Will the solar panels work during a power cut?
Only if the system was designed for it. In a standard installation the solar inverter shuts down with the grid, so the roof produces nothing until the supply returns. A backup-capable system with the array on the backed-up side can recharge the battery in daylight; one without cannot, and the battery runs down until the grid is back. It is a one line question for the installer, and it decides whether a daytime cut is a minor inconvenience or a countdown.
Ask before you sign
“In a power cut, does this system supply anything, which circuits, at what maximum load, for roughly how long at that load, and will the solar still charge the battery?”
If the answer is that it shuts down, that is a normal and correct installation. You just need to know now, rather than during the first storm, and if backup matters to you, the time to buy it is while the consumer unit is already open and the installation is already scaffolded and priced.
Check your own numbers
Backup adds nothing to the cycling arithmetic, so the calculator does not model it; what it does model is whether the battery pays on its everyday job, which is the case the backup premium sits on top of. Start from a 4 kW array with a 10 kWh unit and judge the battery on that before adding the backup cost: open the calculator with the worked example loaded.
Backup and tariff savings can come from the same unit, which is why a battery without solar is worth reading alongside this, and the other battery questions are under home battery storage: costs, sizing and whether it pays. When you are ready for quotes, our installer directory lists Google’s listings near a postcode; check each firm’s certification on the MCS register before you rely on it.
Sources
- Energy Networks Association, Connect my generation, the G98 and G99 connection routes. Checked 2026-10-19, energynetworks.org.
- Tesla, Powerwall warranty (European warranty region), Rev 1.16 effective 3 December 2025, covering Powerwall 2 AC and Powerwall 3: backup listed as a covered application in the UK table at 80% retention and unlimited cycles; Backup Gateway listed as a covered part; Limitation on Use clause on life-support and medical equipment. Checked 2026-10-20, tesla.com.
- GivEnergy, Giv-Bat 9.5 Gen 3 datasheet: not readable by automated check on the date shown, so no backup terms are claimed from it. Checked 2026-10-19, givenergy.co.uk.
- The 300 watt essential load, the 3 kilowatt evening and the quote box are illustrations, labelled as such.
Related
- What size battery for your solar arraySize to your evening use, not to your array. A method using half hourly data, and why oversizing is the more expensive mistake.
- What home battery storage costs in the UKCost per usable kilowatt hour is the only figure that compares batteries fairly, and it is the one quotes are least likely to give you.
- Home battery storage without solar: does it pay?Tariff arbitrage alone can justify a battery. When the spread between cheap and expensive rates makes the sums work, and when it does not.