Skip to content
gowith.solar

How long could your battery keep things running?

Start with the things you need: lights, fridge and Wi-Fi. See how energy capacity and power limits answer two different questions.

Your situation

Appliances to keep running

Example ratings to replace with the rating plate. Time running is the share of time it draws power.

Choose a home like yours
Or search the examples
Search, for example fridge
Fridge-freezer
Wi-Fi router
LED lights
Your battery when the power fails

Usable, not total, capacity from the datasheet.

Backup power limitsEnergy decides how long; power decides what can run at once.

Check both the surge rating and how long it can be held.

Fill from a reviewed battery datasheet

Optional

Choose the exact model. Only figures checked against the manufacturer's document can fill an input. You can always type your own.

Manufacturer
Search manufacturers
Exact model
Choose a manufacturer first
More assumptionsdischarge efficiency, battery and inverter standby draw

What your battery can run in a power cut

Power: what can run at once

Measured in kW, the rate of use at any moment.

All running together0.202 kW of 3.6 kW
The line marks the continuous output you entered.
All starting togetherClosest to its limit0.652 kW of 5 kW
The line marks the surge output you entered.

Energy: how long it lasts

Measured in kWh, the amount stored.

Starting charge, reserve kept back
80%, 10% reserve
Energy you can use
6.65 kWh
At an average 117 W, standby included
About 2 days 9 hours
Power limits decide what can run together; stored energy decides how long it lasts. Both come from the ratings you entered.

Calculated from your figures

Around 2 days 9 hours of backup

Available energy
6.65 kWh
Average load including standby
117 W
All running together
202 W
All starting together
652 W

What this means

An energy estimate for this appliance mix. Real cycling, battery temperature and backup wiring change the result.

How this was calculated

Based on the figures you entered.

  • Requires installed, enabled backup equipment and supported backup circuits.
  • No solar recharging is assumed during the outage. Appliance duty cycles are your entered averages.
  • All selected loads are checked together; surge demand conservatively assumes simultaneous starts.
  • Discharge efficiency includes the battery-to-load losses you enter; standby draw is then added as a separate continuous load.
  • A power limit failure prevents a runtime estimate. Peak duration and motor-start compatibility need the equipment documentation.

Method battery-backup-v1

The working

The maths, step by step

available energy (kWh)=10×max⁡(0,80−10)/100×95/100≈6.65\text{available energy (kWh)} = 10 \times \max(0, 80 - 10) / 100 \times 95 / 100 \approx 6.65
average load (W)=standby+∑(running watts×quantity×duty fraction)≈117\text{average load (W)} = \text{standby} + \sum(\text{running watts} \times \text{quantity} \times \text{duty fraction}) \approx 117
runtime (hours)=6.65×1000÷117≈56.837607\text{runtime (hours)} = 6.65 \times 1000 \div 117 \approx 56.837607

The tool separately checks simultaneous running and starting loads against the entered power limits. It assumes no solar recharging and does not establish backup wiring or motor-start compatibility.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Energy available above the reserve

The starting charge and reserve determine what proportion of usable battery capacity is available for this scenario. The entered discharge efficiency allows for battery-to-load losses.

The result assumes the home has suitable, enabled backup equipment and that the selected appliances are connected to supported backup circuits. A normal grid-connected solar installation does not necessarily provide power in an outage.

Power and energy answer different questions

The calculator adds the entered running loads and conservatively checks the starting loads together against the continuous and peak power limits. If those limits are exceeded, it does not offer a runtime.

When the power check passes, the average load uses each appliance's duty cycle and quantity, plus standby consumption. Available energy divided by that average gives the illustrative runtime.

Check the limits of the estimate

No solar recharging during the outage is assumed. Appliance cycling, battery temperature, standby draw and the actual starting sequence can change the result.

Peak duration, motor-start compatibility and the circuits supported depend on the equipment and installation. Check the documentation and ask your installer before relying on backup.

Take it further

Solar and battery ROI calculator

Would this battery earn its keep?

The ROI calculator adds a battery to a full solar projection: charging from surplus, cheap-rate tariffs, capacity fade and the replacement year.

Open the ROI calculator

Before you rely on this

Start with the things you need: lights, fridge and Wi-Fi. See how energy capacity and power limits answer two different questions.

  • Use your equipment's ratings. The example appliances are editable illustrative loads.
  • Average consumption estimates runtime; simultaneous loads and starting surges determine whether appliances can run.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

How long will a home battery run my essentials in a power cut?

The tool takes the usable capacity, the charge you start with and the reserve kept back, applies discharge efficiency, then divides by the average power your chosen appliances draw plus the battery's own standby draw. The result is a runtime in hours. It assumes backup equipment is installed and enabled, and that the battery is not recharged by solar during the outage.

Can my battery run the kettle and oven in a power cut, or only essentials?

The tool adds up all the appliances you list and checks them together against the battery's continuous output. If they exceed it, it reports a power limit problem instead of a runtime. A large load such as a kettle can fail that check even when the battery holds plenty of energy, because power and energy are separate limits.

Why does the battery's power rating matter as well as its kWh size?

The kWh figure decides how long the battery can run, while the kW output decides what can run at the same time. The tool checks both, including a short surge limit for appliances that draw more when they start. Surge demand is checked as if everything started together, which is cautious, and how long a surge can be held is not modelled.

How does the tool treat a fridge that cycles on and off?

Each appliance has a running wattage, a surge wattage, a duty cycle and a quantity. The duty cycle is the share of time it is drawing power, so a fridge-freezer uses a lower average than its running watts. The example appliances are editable and illustrative, so replace them with figures from your own equipment.

Why is the usable battery capacity not the same as the number on the box?

Manufacturers often quote total capacity, but some of it is not available to use. The tool asks for usable capacity from the datasheet, then subtracts the reserve you keep back and applies the discharge efficiency you enter. Using the total figure would overstate the runtime.