gowith.solar

Microinverters against power optimisers

Both solve shading. They fail differently, cost differently and are serviced differently, and the shading assessment tells you whether to buy either.

11 min readcomparison
Illustration accompanying Microinverters against power optimisers

Explore this decision

Microinverter vs string inverter calculator: compare your quotes

Compare installed costs and an illustrative annual value for extra generation.

Extra generation and its value are entered assumptions, not a prediction of shading gains.

Open microinverter vs string on its own page

Explore this decision

Solar shading loss calculator: explore a generation scenario

Apply an assumed shading energy loss to baseline solar generation for the same period.

A shading energy-loss percentage is not the same as the percentage of panel area shaded.

Open shading loss scenario on its own page

Both solve the same problem: on a plain string inverter, one shaded or underperforming panel drags down every panel wired in series with it. Both break that dependency by managing each panel individually.

They differ in where the conversion happens, and that difference shows up in cost, in failure behaviour and in servicing. Before either, though, the question is whether your roof needs per-panel electronics at all, because the answer has a number attached.

Price the problem before the solution

The MCS installation standard, MIS 3002, requires a certified installer’s generation estimate to carry a shade factor: “1 minus estimated loss”, so a roof losing 11% to shade has a factor of 0.89, and a clear horizon gets 1.00. That factor is the budget for this decision. Suppose it says shading costs a plain string system 15% of output. On a 4 kW array generating 3,400 kilowatt hours at the site model’s 850 per kilowatt, that is about 510 kilowatt hours a year; valued somewhere between Octopus Outgoing’s 12p export rate and the October to December 2026 cap of 26.32p, call it £61 to £134 a year depending on your self consumption. That annual figure, across the system’s life, is what the per-panel electronics premium is bidding against.

If the assessment says shading costs 2%, the answer is a plain string inverter and the premium would return more as an extra panel. If it says 15%, read on.

A worked household: the shaded semi

A 4 kW south facing array at the DESNZ 2025/26 median for systems up to 4 kW, £1,780 per kilowatt, £7,120, on a house using 3,400 kWh with a chimney and a neighbour’s tree costing a plain string system 15%. Half the generation is used at home.

  • Plain string inverter: about 2,890 kWh a year. Used at home 1,445 kWh at 26.32p, about £380; exported 1,445 kWh at 12p, about £173; about £553 a year, payback about 12.9 years
  • With optimisers recovering most of the loss, say 12 of the 15 points: about 3,298 kWh. About £434 and £198, about £632 a year, about £79 more than the plain system

The optimisers’ premium is the installer’s line, not a published figure; at an illustrative £60 a panel, £600 on ten panels, the extra £79 a year recovers it in about 7.6 years, inside the system’s life, and the array with optimisers pays back in about 12.2 years on £7,720 against 12.9 without them. At £1,200 the premium takes 15 years and the case is marginal. The widget below runs the plain string case at the shaded yield of about 722 kWh per kilowatt; change the share used at home and the export tariff to see what the recovered output is worth on your roof.

Try the numbersHow the self consumption share moves payback
4 kW
£1,780
50%
Installed cost
£7,120
Annual generation
2,888 kWh
Avoided import (1,444 kWh)
£380
Export income (1,444 kWh)
£173
Annual saving, today's money
£553
Simple payback
12.9 years
Simple payback at 25% used: 15.8 years, 50% used: 12.9 years, 75% used: 10.8 years. The highlighted bar is the share you set.Simple payback at 25% used: 15.8 years, 50% used: 12.9 years, 75% used: 10.8 years. The highlighted bar is the share you set. Values: 25% used: Simple payback 15.8 years; 50% used: Simple payback 12.9 years; 75% used: Simple payback 10.8 years.15.8 years25% used12.9 years50% used10.8 years75% used
  • Your share
  • Other bars
Assumptions
  • Import at 26.32p, the Ofgem price cap unit rate (Ofgem cap, 1 October to 31 December 2026).
  • 722 kWh generated per kW a year, the article's illustrative postcode estimate rather than the site model's 850 kWh.
  • Cost per kW starts at the DESNZ median installed cost per kW, 4 to 10 kW (2025/26 edition, published 28 May 2026, confirmed against the spreadsheet 2026-10-19): £1,697. The 0 to 4 kW median is £1,780.
  • Year one only: no degradation, no inverter replacement, no standing charge, no battery.

Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.

What each one is

Power optimisers are small units fitted behind each panel. They manage that panel’s electrical operating point and pass optimised direct current down the string to a single central inverter, which does the conversion to alternating current.

Microinverters are complete small inverters fitted behind each panel. Each converts at the panel, so what runs down from the roof is already alternating current.

The practical difference: with optimisers there is still one central box doing the conversion. With microinverters there is not.

How they fail

This is the most useful way to tell them apart.

A central inverter failure stops the entire system. With optimisers, that single point of failure remains. The compensation is that the inverter is at ground level or in the loft, accessible, and replacing it is a familiar job at a familiar price: a UK retailer listed a Sungrow 5 kW single phase hybrid inverter at £899.99 including VAT on 20 October 2026, before labour.

A microinverter failure stops one panel. The rest carries on. The compensation is that there are as many units as panels, all on the roof, so replacing one means roof access and possibly scaffolding, which can cost more than the failed unit.

Neither is obviously better. One concentrates risk in an accessible place; the other distributes it into an inaccessible one. What tips it is how you weight a rare total outage against occasional single-panel attrition, and whether your monitoring habits would actually notice the latter.

The two on the same axes

Plain string inverterString plus optimisersMicroinverters
Where conversion happensOne central boxOne central box, per-panel DC managementAt each panel
Shading recoveryNonePer panelPer panel
Single point of failureYes, accessibleYes, accessibleNo; per-panel units on the roof
Central inverter replacement in the projectionYes, typically inside 25 yearsYesNone
Per-panel monitoringNoYesYes
Loft DC cabling at string voltageYesYesNo
Adding panels laterString redesignString redesignAdd a panel and its unit
Typical costLowestMiddleHighest per watt

A second household: the complicated roof

Three small pitches at different angles, nine panels in all, on a house using 3,400 kWh. A string inverter would need its inputs matched to pitches that do not match; optimisers make one string tolerate the mix; microinverters make each panel its own system. On the generation side the two per-panel options land in the same place. The difference is the maintenance line: the optimiser household budgets one central inverter replacement, about £900 plus labour at the retail price above, somewhere around the warranty’s end; the microinverter household budgets none, and instead carries the risk of a roof visit per failed unit. Over 25 years, if two microinverters fail and each visit costs an illustrative £300 with no scaffold, the two households have spent about the same. With a scaffold each time, the microinverter household has spent more. That is the comparison the acronyms hide.

Cost

Optimisers add a per-panel cost on top of a conventional string inverter.

Microinverters replace the string inverter entirely, so the comparison is not simply additive, but they generally come out highest per watt of the three options.

A plain string inverter remains cheapest, and on an unshaded single-orientation roof it is the right answer. An optimiser line on a quote for a clean south-facing pitch is one of the legitimate questions to put to an installer: sometimes there is a shading reason you had not seen, and sometimes the line is margin wearing an acronym.

What the quote will say

Optimisers included: maximises your generation and monitors every panel.

Ask for the MIS 3002 shade factor on the performance estimate. If it is 1.00, the roof has a clear horizon and the optimisers are recovering nothing; the per-panel monitoring is the only thing you are buying, and it has a price. If it is 0.85, the optimisers are worth about £79 a year on the worked household and the quote should show the premium as a line so you can divide one by the other.

Where each suits

Optimisers suit a roof with some shading, or two orientations, where you still want a single point of monitoring and a familiar central unit. They are the most commonly specified of the two in the UK.

Microinverters suit a complicated roof: several small pitches at different angles, awkward shapes, or a plan to extend the array later. Adding a panel means adding its microinverter, with no string design to rework.

They also avoid high-voltage direct current cabling in the loft, which some people prefer for fire-risk peace of mind, and they eliminate the central inverter replacement from the maintenance budget entirely.

When the plain string inverter wins: a clear horizon, one pitch, and no plan to extend. Its shade factor is 1.00, its replacement is one accessible box, and every pound not spent on per-panel electronics is a pound towards another panel, which on a roof with room is the cheapest capacity there is.

Monitoring

Both give per-panel data, which is genuinely valuable and rarely mentioned in sales conversations.

Per-panel monitoring means you can see one panel underperforming, which is how you spot a bird dropping, a developing fault or a newly grown branch: the monthly monitoring habit becomes far more precise when each panel reports separately. A plain string system reports one number, and a single failing panel hides inside it for months.

If you are choosing between systems partly on monitoring, check what the app actually shows and whether historical data is retained, because the year-on-year comparison is the check that catches slow problems.

Warranty and longevity

Microinverters typically carry long warranties, some as long as the panels themselves, which they need to, being on the roof and numerous.

Optimisers carry long warranties too, but the central inverter they feed does not: it has a conventional inverter lifespan and will need replacing during the system’s life. Budget for that, in the year you expect it, the way any honest projection does.

Ask specifically what happens if the manufacturer of the per-panel electronics leaves the market. Proprietary systems tie the panels to that manufacturer’s ecosystem, which is a mild lock-in worth knowing about before the roof is populated with it.

Questions people ask

Are optimisers worth it without shading?

For output, no: with a shade factor of 1.00 there is no lost generation to recover, and the premium buys only per-panel monitoring. On the worked household the recovered output at a 15% loss is worth about £79 a year; at 0% it is worth nothing, and the same money is better spent on another panel or on nothing.

How much output does shading cost?

Whatever the installer’s shade assessment says, and MIS 3002 requires it to be stated as a factor on the estimate. A 15% loss on a 4 kW array is about 510 kWh a year, between £61 and £134 depending on how much of it would have been used at home. On a plain string one chimney can cost more than its shadow suggests, because the shaded panel sets the current for every panel wired in series with it.

Do microinverters need replacing?

Individually, when one fails, with a roof visit each time; the central inverter replacement that a string or optimiser system carries once in its life does not apply. Over 25 years the two patterns can cost about the same if a couple of microinverters fail and the visits need no scaffold, and more if they do; the inverter lifespan post covers when the central inverter is likely to need replacing.

Can I add optimisers later?

Usually, to a compatible string inverter, but the roof work is the cost: each unit sits behind a panel. If shading is a known problem, fit them with the panels; if it is a future tree, the per-panel monitoring of either option is what tells you when the time has come.

Check your own numbers

Ask your installer to quantify it: what is the annual generation estimate with a plain string inverter, and what is it with per-panel electronics? The MIS 3002 shade factor gives them the basis, and the gap between the two figures, priced at your rates, is the entire financial case. The calculator runs the projection for either generation figure with your usage and tariff, degradation and the inverter replacement in it, in today’s money. Start from the shaded semi and compare the two system sizes the shade factor implies: open the calculator with the worked example loaded.

The rest of the hardware is explained under how solar panels and inverters actually work. When you are comparing quotes, our installer directory lists Google’s listings near a postcode; check each firm’s certification on the MCS register before you rely on it.

Sources

  • MCS, MIS 3002 The Solar PV Standard (Installation), issue 6.0 dated 18 March 2026: the shade factor in the performance estimate. Checked 2026-10-20, mcscertified.com.
  • Department for Energy Security and Net Zero, Solar PV cost data, 2025/26 edition published 28 May 2026, median of £1,780 per kilowatt for systems up to 4 kW. Checked 2026-10-19, gov.uk.
  • Ofgem, Changes to the energy price cap between 1 October and 31 December 2026: 26.32p per kWh. Checked 2026-10-20, ofgem.gov.uk.
  • Octopus Energy, Smart Export Guarantee: Outgoing at 12p. Checked 2026-10-19, octopus.energy.
  • Eco Wizard, Inverters listing: Sungrow 5 kW single phase hybrid inverter at £899.99 including VAT. Checked 2026-10-20, ecowizard.co.uk.
  • gowith.solar, What the calculator models, for the 850 kWh per kilowatt figure, what the calculator models.
  • The 15% shade loss, the 12 points recovered, the £60 a panel premium, the £300 roof visit and the 50% share are illustrations, labelled as such.