Cost per kWp: the only figure that compares two quotes

Why the headline total tells you almost nothing, and how one division makes three quotes comparable.

9 min readcalculation
Illustration accompanying Cost per kWp: the only figure that compares two quotes

Explore this decision

Solar installation cost calculator: add up your quote

Break down entered panel, equipment, installation and access costs for a solar quote.

Each amount is entered once on a consistent VAT basis.

Open solar installation cost on its own page

Three quotes, three totals, and no obvious way to compare them. One division fixes that: divide each total by the system size in kilowatts peak.

Cost per kWp is the only figure that makes differently sized systems comparable, it takes about thirty seconds to work out, and, unusually for this market, there is official data to hold your results against once you have them.

The calculation

  1. Find the system size on each quote, in kWp. It is usually near the top, sometimes expressed as panel count multiplied by panel wattage. Twelve panels at 440W is 5.28 kWp.
  2. Take the total price, including VAT, which for a qualifying domestic job should currently be zero, so the total and the ex-VAT figure should match.
  3. Divide.

A worked set: £8,900 for 5.28kWp is £1,686; £7,200 for 4.0kWp is £1,800; £6,400 for 3.52kWp is £1,818. The £2,500 spread in totals was mostly capacity: on a per kWp basis the “dearest” quote is the cheapest, and the real conversation is about why the smallest system carries the highest rate, which the fixed-cost section below answers.

Try the numbersSize, generation and your quote against the median
440 W
12
£8,900
System size
5.28 kWp
Year one generation
4,488 kWh
DESNZ band, 4 to 10 kW
£1,697 per kW median
Median cost for this size
£8,960
Your quote per kWp
£1,686
Against the median
-0.67%
Assumptions
  • 850 kWh per kW a year for a south facing roof (the site model's figure, not a measurement), scaled by the calculator's direction factors shown in the list.
  • Pitch and shading are not modelled here. For a roof-specific figure use PVGIS, which is free, or the MCS estimate on the quote.
  • Medians are the DESNZ median installed cost per kW, 0 to 4 kW (£1,780) and 4 to 10 kW (£1,697), 2025/26 edition, published 28 May 2026, confirmed against the spreadsheet 2026-10-19. No larger domestic band is published.
  • The quote starts at the median for the size shown, so the comparison reads zero until you enter your own total. 440 W per panel is the posts' worked figure; use the wattage on your quote.

Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.

Then anchor against the official medians

The Department for Energy Security and Net Zero publishes per kilowatt costs from real certified installations. For 2025/26 the medians are £1,780 per kilowatt for systems up to 4kW and £1,697 for 4 to 10kW, with regional means showing Scotland, Wales and the North East cheapest and London and the South West at the top.

That gives your normalised numbers an external reference no installer controls. A quote well above the medians needs a nameable reason; one far below them deserves suspicion, because the medians describe what real, certified, warranted work costs. All three quotes in the worked set sit inside the plausible band, which is itself information: nobody is trying it on, and the decision moves to specification.

Against their own bands: the 5.28kWp quote is about 0.6% below the 4 to 10kW median, the 4.0kWp quote about 1.1% above the 0 to 4kW median, and the 3.52kWp quote about 2.1% above it. Three quotes within a few percent of the official middle, from three different sizes, is what a competitive, properly surveyed set looks like.

A second worked set, where the division changes the winner

The first set was close once normalised. This set is not, and it shows what the division is for:

  • Quote D: ten panels at 430W, 4.3kWp, £7,100. That is £1,651 per kWp, about 2.7% below the 4 to 10kW median.
  • Quote E: eight panels at 540W, 4.32kWp, £8,650. That is £2,002 per kWp, about 18% above the same median.
  • Quote F: fourteen panels at 440W, 6.16kWp, £9,900. That is £1,607 per kWp, about 5% below it.

On totals, D looks cheapest and F dearest. Per kWp, F is the cheapest capacity by a clear margin and E is the outlier, carrying an 18% premium for almost the same capacity as D. E is the quote to question, and the question is specific: eight high-wattage panels is the roof-constrained specification, so is this roof actually constrained, and if so does the premium buy the only capacity that fits, or is it margin? Without the division, E’s total sits plausibly between the other two and the question never gets asked.

Why it works

Almost everything that varies between quotes scales with capacity or does not. Dividing by capacity normalises the first group and exposes the second.

What remains is a genuine difference, and it will be one of four things:

Equipment tier. Better panels, a better inverter, longer warranties.

Per-panel electronics. Optimisers or microinverters, specified because the roof has shading or splits across orientations. Materially more expensive and often correct, which is why normalising quotes is step one of comparing them, not the whole job.

Site difficulty. A slate roof, restricted access, a long cable run, an old consumer unit.

Margin. Sometimes simply higher.

Only the last is something to push back on, and you cannot see it until the other three are accounted for.

Why small systems look expensive

The fixed costs are the reason, and the full breakdown itemises them: scaffolding priced by the property, the survey, certification and network notification unchanged by size, one inverter covering a range of capacities.

Spread across a small system, those fixed costs dominate, and cost per kWp is poor, which is exactly what the official data shows in the gap between its two size bands. Spread across a larger one, they dilute.

This is the most useful thing the metric tells you: adding capacity to a job that is happening anyway is cheap, and the marginal panel costs far less than the average. If your roof and your consumption both support more, the extra capacity is the best-value part of the whole purchase, and the sizing question is worth revisiting before you accept the quoted size.

What the quote will say

Premium 540 W panels. Only 8 panels needed for a 4.3 kW system. £8,650 installed.

“Only eight panels” is doing the work of a per kWp figure without stating one. Eight panels at 540 W and ten at 430 W are the same capacity within a rounding error; the premium is for fitting it into less roof, which is worth paying for if the roof is the constraint and not otherwise. Divide by the kilowatts and the sentence becomes “£2,002 per kWp against a median of £1,697”, which is the sentence to ask about.

The trap

Cost per kWp is a comparison tool, not an objective to minimise.

The cheapest cost per kWp is achieved by fitting the largest possible array with the cheapest possible equipment. That is not the best system if:

  • The extra generation exceeds what you can use, so it exports at a rate less than half your import rate.
  • The roof has shading that cheap equipment handles badly.
  • The panels chosen are physically larger and you are area-constrained.

Use it to compare quotes for similar specifications. Do not use it to choose a specification.

What to record for each quote

  • Total price including VAT.
  • System size in kWp.
  • Cost per kWp.
  • Inverter type, and whether it is battery-ready.
  • Estimated annual generation, and the tool that produced it.
  • What is excluded.

Six lines per quote. With those in front of you, the conversation with an installer changes completely, because you are asking about specific differences rather than asking them to justify a total.

The follow-up question

Once you have the figures, ask the dearest installer:

“Your cost per kWp is higher than the others for a similar specification. What does that buy me?”

A real answer names something concrete: a harder roof, better equipment, optimisers for shading you had not noticed. A vague answer about quality is telling you the difference is margin.

Questions people ask

Which median do I compare a 4.3kWp quote with?

The 4 to 10kW band, because 4.3 is above four. The bands are by declared capacity, and a system that straddles the line is the case where the per kWp rate drops most sharply for a small step in size, which is one reason quotes cluster just above and just below four kilowatts. If your quote is 3.9kWp, ask what 4.2kWp would cost; the answer per kWp is often better.

Should I include the battery in the division?

No. A battery is priced per kilowatt hour of storage, not per kilowatt of panels, and folding it into the solar total makes a combined quote look expensive per kWp for no reason. Split the quote into the array and the storage, divide each by its own unit, and compare the solar part against the DESNZ medians and the battery part against the cost per kilowatt hour figures.

Do the medians include VAT?

The DESNZ data is built from certified installation records, and for domestic work in the period the zero rate applied there is no VAT inside the figures to strip out. Compare your quote’s total including whatever VAT it shows; for a qualifying domestic job that total should carry none, and if it carries 20% the comparison will tell you so before the accountant does.

What about regional differences?

The regional means in the same release run from Scotland, Wales and the North East at the cheap end to London and the South West at the dear end, a spread of a few hundred pounds per kilowatt in the 0 to 4kW band. A quote in London a little above the national median is in line with its region; the same quote in Scotland is above both. Use the regional figure when the release publishes one for your area.

Check your own numbers

Cost per kWp compares purchases. It says nothing about whether the purchase is worthwhile, which depends on your consumption and your tariff. Take the normalised cost and a conservative generation estimate, apply your own import and export rates separately, and run the projection. The worked 4kW example shows the shape: a median-priced system, honestly modelled, pays back in about eleven years for a household using half its generation, and every hundred pounds per kilowatt you save against the median arrives straight off that payback. Start from the 5.28kWp quote: open the calculator with the worked example loaded.

Next: the step up to 6 kW, reading a quote line by line, and the rest of the cost guides. If you still need businesses to quote, our installer directory lists Google’s listings near a postcode; check each one’s MCS status on the register.

Sources

  • Department for Energy Security and Net Zero, Solar PV cost data, 2025/26 edition published 28 May 2026, DNC basis spreadsheet: medians of £1,780.25 (0 to 4kW) and £1,696.97 (4 to 10kW) per kilowatt, and the regional means table. Checked 2026-10-19, gov.uk.
  • HMRC, VAT on energy-saving materials and heating equipment, Notice 708/6. Checked 2026-10-19, gov.uk.
  • The six quotes in the two worked sets are illustrations, not real quotes.