gowith.solar

East and west facing panels: the split array

Lower annual total, better match to a morning and evening household. Worked in pounds for three households, and how to tell which one you are.

11 min readcomparison
Illustration accompanying East and west facing panels: the split array

A south-facing array produces the largest annual total. An east-west split array produces less, and quite often saves the household about the same money. Those two statements are not in conflict, and the reason is self-consumption.

If your roof runs east to west, you have not been dealt a bad hand. The arithmetic below shows how small the penalty really is, which household it bites, and the one design mistake that makes it larger than it needs to be.

What the two shapes actually do

South-facing concentrates generation into a pronounced peak around the middle of the day. The annual total is the highest available: in the site model, 850 kilowatt hours per kilowatt per year.

East-west, with panels on both pitches, produces two smaller humps: one through the morning from the east side, another through the afternoon and early evening from the west. The calculator scales an east or west roof to 85% of south, so a 4 kW east-west array generates about 2,890 kilowatt hours against a south-facing 3,400, and the generating day is noticeably longer. The European Commission’s PVGIS tool will produce hour-by-hour profiles for your own roof and pitch, free, if you want to see the two humps at your latitude.

The widget converts a panel count into capacity and year one generation on the calculator’s direction factors, and holds a quote against the DESNZ median. It starts on the worked 4 kW array facing east or west; switch the direction to south to see the 510 kWh difference.

Try the numbersSize, generation and your quote against the median
400 W
10
£7,120
System size
4 kWp
Year one generation
2,890 kWh
DESNZ band, 0 to 4 kW
£1,780 per kW median
Median cost for this size
£7,120
Your quote per kWp
£1,780
Against the median
0%
Assumptions
  • 850 kWh per kW a year for a south facing roof (the site model's figure, not a measurement), scaled by the calculator's direction factors shown in the list.
  • Pitch and shading are not modelled here. For a roof-specific figure use PVGIS, which is free, or the MCS estimate on the quote.
  • Medians are the DESNZ median installed cost per kW, 0 to 4 kW (£1,780) and 4 to 10 kW (£1,697), 2025/26 edition, published 28 May 2026, confirmed against the spreadsheet 2026-10-19. No larger domestic band is published.
  • The quote starts at the median for the size shown, so the comparison reads zero until you enter your own total. 440 W per panel is the posts' worked figure; use the wattage on your quote.

Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.

Why the flatter shape can earn as much

The value of a generated unit depends entirely on whether you use it. Used at home it avoids the October to December 2026 cap of 26.32p; exported it earns 12p on Octopus Outgoing. Each unit moved from export into use is worth about 14.3p, so a shape that lines generation up with the household can make up for a smaller total.

A worked household: commuters on a terrace

A 4 kW array at the DESNZ 2025/26 median for systems up to 4 kW, £1,780 per kilowatt, £7,120, on a household out from half past eight to half past five. On a south roof the midday peak mostly misses them: say 30% used at home. On an east-west roof the morning and early-evening humps overlap breakfast and homecoming: say 50%. Both shares are illustrations; yours come from your own routine and your smart meter.

  • South, 3,400 kWh: 1,020 used at 26.32p is about £268; 2,380 exported at 12p is about £286. About £554 a year, payback about 12.9 years.
  • East-west, 2,890 kWh: 1,445 used is about £380; 1,445 exported is about £173. About £554 a year, payback about 12.9 years.

Fifteen percent less generation, under a pound of difference. The correct comparison is pounds, not kilowatt hours, and in pounds the two roofs finish level for exactly the household that worries most about facing the wrong way.

A second household: someone home all day

Now the same 4 kW on a house with someone home through the day, using 60% of what either roof makes. The midday peak is no longer wasted, so the south roof’s larger total counts in full.

  • South: 2,040 used, about £537; 1,360 exported, about £163. About £700 a year, payback about 10.2 years.
  • East-west: 1,734 used, about £456; 1,156 exported, about £139. About £595 a year, payback about 12.0 years.

Here south wins by about £105 a year, roughly the 510 kWh shortfall valued at the higher, mostly-used rate. The orientation penalty is real for a household that already soaks up midday generation, and close to nothing for one that does not.

A third household: the roof with room

The quiet decider is area. A south-only house often has one usable pitch; an east-west house has two. Where the south semi fits ten panels, the east-west terrace may fit twelve 440 W panels across both pitches, 5.28 kWp.

  • Generation: 5.28 times 850 times 0.85, about 3,815 kWh, more than the south 4 kW roof’s 3,400.
  • Cost at the DESNZ 4 to 10 kW median of £1,697 per kilowatt: about £8,960.
  • For the commuting household at 50% used: about £502 used and £229 exported, about £731 a year, payback about 12.3 years.

That is about £177 a year more than either 4 kW roof for about £1,840 more, an increment that pays back in about 10.4 years, inside the system’s life. To match the south roof’s total exactly, 4.71 kW on an east-west roof does it: twelve 400 W panels, 4.8 kWp, make about 3,470 kWh.

The two roofs on the same axes

South, 4 kWEast-west, 4 kWEast-west, 5.28 kWp
Direction factor in the calculator100%85%85%
Year one generationabout 3,400 kWhabout 2,890 kWhabout 3,815 kWh
Price at the DESNZ median£7,120£7,120about £8,960
Commuters, illustrative share used30%50%50%
Commuters, annual savingabout £554about £554about £731
Home all day, 60% usedabout £700about £595not worked
Strings or MPPT inputs neededOneTwo, one per pitchTwo, one per pitch

Where east-west wins outright

  • Nobody home midday, but home by five. The west side is still producing when the household starts consuming.
  • A wide gap between import and export rates, which raises the value of each unit used rather than exported.
  • No battery, and none planned. Storage is the other way to solve a midday peak; without it, generating closer to when you consume matters more.
  • Roof area to spare, as the third household shows.

Where south still wins

  • High daytime consumption, so the midday peak is absorbed rather than exported, as the second household shows.
  • A battery, which turns the midday peak into evening supply and removes most of the timing advantage.
  • Limited roof area, where you need the most output per panel.
  • A strong export rate, which narrows the penalty for exporting surplus.

The shape through a day, and what to move where

The two humps reward a little household choreography that a south peak never asks for. The east side is strongest from mid-morning: breakfast loads, the washing machine’s first cycle and a home-worker’s morning sit naturally under it. The west side carries the late afternoon: the dishwasher’s pre-dinner run, a car topping up on the drive, a second immersion heat. A south roof asks you to crowd everything into the middle of the day; the split array meets a normal routine roughly where it already lives.

On the commuting household’s 2,890 kWh, moving 300 kWh from export into use with a couple of timed plugs is worth about £43 a year at 14.3p a unit. The widget runs that on your own figures; change the share and the shifted units and watch the split.

Try the numbersA unit used against a unit sold
2,890 kWh
50%
300 kWh
Used at home, 1,445 kWh
£380
Exported, 1,445 kWh
£173
A 2p better export rate is worth
£29 a year
Moving 300 kWh into daylight is worth
£43 a year
The units used at home are worth £380 a year and the units exported £173.The units used at home are worth £380 a year and the units exported £173. Values: Used: Pounds a year £380; Exported: Pounds a year £173.£380Used£173Exported
  • Used at home
  • Other bars
Assumptions
  • Import at 26.32p, the Ofgem price cap unit rate (Ofgem cap, 1 October to 31 December 2026); export at the rate selected, from the Octopus SEG page (checked 2026-10-19).
  • The gap between the two rates is 14.32p: what every kilowatt hour moved from export to use is worth. A 2p better export rate is the article's comparison, applied to the units still exported.
  • Generation and the share used are yours to set; the shift is capped at what is exported. Year one, nothing inflated.

Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.

The practical detail: two strings

An east-west array should be wired as two strings, one per orientation, or use per-panel electronics.

The reason is the same series behaviour that makes shading costly. Panels at different orientations produce different currents at any given moment, and putting them on one string means the weaker side constrains the stronger, all day, every day.

An installer proposing a single string across both pitches has either not thought about it or is cutting cost somewhere it matters. Ask directly how the array is strung, and if the answer is one string, ask why. The inverter needs two inputs with independent maximum power point tracking, which most modern units have, but confirm it on the inverter’s datasheet rather than the brochure. Optimisers or microinverters are the alternative where a pitch is also shaded.

Sizing

Because generation per kilowatt is lower, an east-west array needs more panels to reach the same annual output. That is usually fine, since you have two pitches to use, and the marginal panel is cheap once the scaffolding is up.

Because the two pitches never peak at the same moment, the combined output peaks lower than the same capacity facing south, which is why inverters on split arrays are often sized below the panels’ total. Ask the installer what inverter rating they propose and what clipping, if any, their estimate allows for. The same zigzag logic is how flat roofs pack capacity.

What the quote will say

4.4 kWp east-west system. Estimated generation: 3,600 kWh a year.

On the calculator’s factors, 4.4 kWp facing east and west makes about 3,180 kWh; 3,600 is closer to what the same panels would make facing south. Ask for the generation estimate split by orientation, with the MCS method’s location, orientation and shade factors for each pitch. If the honest figure is 3,180, the quote has overstated about 420 kWh a year, about £80 at a 50% share, every year of the projection.

Questions people ask

Are east and west roofs worth putting panels on?

Usually, yes. On the calculator’s model each pitch gives up 15% against south, so a 4 kW split array makes about 2,890 kWh against 3,400. For a commuting household that uses more of what the split array makes, the annual saving can come out level, about £554 each on the worked figures. The household it suits least is the one already home all day, where south is worth about £105 a year more.

Is an east roof better than a west one?

The calculator treats them alike, at 85% of south. Which suits you depends on when the house uses power: a household home in the late afternoon gets more from the west side, an early-rising one from the east. If you only have one of the two, a smart meter’s half-hourly data shows which half of the day your load sits in.

How many extra panels make up the difference?

On the site model, about 18% more capacity: 4.71 kW facing east and west makes what 4 kW makes facing south. In whole panels that is twelve 400 W panels instead of ten, if both pitches have room. Price the two extra panels on the same scaffold, which is the cheapest capacity there is.

Does a battery make east-west pointless?

It narrows the advantage, because a battery moves the midday peak into the evening on any roof. It does not make the split array worse: the total is still 15% lower, and the battery still cycles. If storage is planned, compare the two roofs with the battery in both and see which saves more; the shape matters less, the total more.

Check your own numbers

Ask any installer quoting an east-west system for the generation estimate split by orientation and, ideally, by month. Then apply your own daytime consumption pattern to it. The calculator scales generation by its direction factor and estimates the share you use from your system size, usage and occupancy; it does not draw the two humps, so the self-consumption advantage of the split array is something to judge from your own routine, then test by changing the occupancy. Start from the commuting household facing east and compare it with south: open the calculator with the worked example loaded.

On a roof short of space, panel efficiency is the other lever, and the rest of the hardware is explained under how solar panels and inverters actually work.

Sources

  • Department for Energy Security and Net Zero, Solar PV cost data, 2025/26 edition published 28 May 2026: medians of £1,780 per kilowatt (0 to 4 kW) and £1,697 (4 to 10 kW). Checked 2026-10-19, gov.uk.
  • Ofgem, Changes to the energy price cap between 1 October and 31 December 2026: 26.32p per kWh. Checked 2026-10-20, ofgem.gov.uk.
  • Octopus Energy, Smart Export Guarantee: Outgoing at 12p. Checked 2026-10-19, octopus.energy.
  • European Commission Joint Research Centre, PVGIS, for hourly profiles by orientation and pitch, re.jrc.ec.europa.eu.
  • gowith.solar, What the calculator models, for the 850 kWh per kilowatt figure, the 85% east or west factor and how the share used is estimated, what the calculator models.
  • The 30%, 50% and 60% shares, the 300 kWh shifted, the twelve-panel roof and the quote box are illustrations, labelled as such.