How much does shading actually cost you?
One shaded panel can drag a whole string. How the MCS shade factor is worked out, what it costs in pounds, and how to check it before an installer does.

Shading costs more than people expect, and it costs more than the shaded area alone would suggest. On a conventional string inverter, one shaded panel drags down every panel wired in series with it.
That is the single most important fact about shade on a roof, it is why a chimney casting a shadow over two panels can cost you the output of eight, and it is measurable in pounds before you buy anything. The certification scheme even prescribes how to measure it, which gives you a number to ask for.
Why one panel affects the whole string
Panels in a string are wired in series, so the same current flows through all of them. A shaded panel produces less current, and because it is in series, it limits the current the whole string can carry.
Bypass diodes inside each panel reduce the damage by routing current around the worst-affected sections, so the loss is not total. But it is far greater than the proportion of the array that is actually in shadow.
An array split across two strings only suffers on the affected string, which is one reason good design puts panels likely to be shaded on their own string, and one reason the string layout on a quote is worth a question even before any electronics are discussed.
How the shade factor is worked out
Every certified installer’s generation estimate is built from one formula in the MCS installation standard, MIS 3002: annual output equals the system’s kilowatts peak, times a yield per kilowatt looked up for the postcode region, pitch and orientation, times a shade factor. The shade factor is “1 minus estimated loss”, so an 11% loss gives 0.89. Where the horizon is obviously clear, the standard lets the installer skip the assessment and use 1.00.
The method MCS publishes for that factor, MGD 005, is deliberately simple. Stand at the centre of the proposed array, look south, and draw the skyline onto a sun path chart: a fan of arcs showing where the sun is at different times of day and year. The chart is divided into 84 segments, each worth 0.01. Count every segment the skyline touches, multiply by 0.01, and subtract from one.
The important refinement is distance. Anything within 10 metres of the array, a chimney, a vent pipe, an aerial, gets a circle drawn on the chart with a radius equal to its height, and every segment inside the circle is counted too. The guidance’s own example shows why: the same object scores 11 segments and a factor of 0.89 when it is far away, and 40 segments and a factor of 0.60 when it is near. Objects to the north of the array do not count, because they cast little if any shadow on it.
Two honest caveats come with the method. MCS says it should land within 10% of the real annual yield for most systems, and it does not credit per-panel electronics at all, because the benefit varies too much between projects. If an installer used a different method, the standard requires them to say so, and to confirm the system will still deliver at least 90% of the estimate.
Put a price on it
Turn the factor into money before deciding anything. The worked figures below use a 4 kW south facing array at the DESNZ 2025/26 median of £1,780 per kilowatt, £7,120, at the site model’s 850 kilowatt hours per kilowatt, 3,400 a year unshaded. Half is used at home at the October to December 2026 cap of 26.32p and half exported at Octopus Outgoing’s 12p, so each generated unit is worth about 19.2p.
A worked household: the distant tree
The skyline to the south-west includes a neighbour’s tree well beyond 10 metres, and the chart count gives the guidance’s far-object figure, 0.89.
- Generation: 3,400 times 0.89, about 3,026 kWh a year
- Lost against a clear roof: about 374 kWh, about £72 a year
- Saving: about £580 a year against about £651 unshaded
- Payback: about 12.3 years against about 10.9
An 11% factor is a real cost, roughly a year and a third added to payback, and on its own it is rarely a reason not to install.
A second household: the chimney in the middle
Same roof, but the obstruction is the house’s own chimney stack, within 10 metres of the panels. The circle rule takes the count to the guidance’s near-object figure, 0.60.
- Generation: 3,400 times 0.60, about 2,040 kWh a year
- Lost against a clear roof: about 1,360 kWh, about £261 a year
- Saving: about £391 a year
- Payback: about 18.2 years
That is the case where design changes the answer. Moving the array off the chimney’s slope, splitting the strings, or fitting per-panel electronics is worth pricing, because each recovered point of factor on this roof is worth about £6.50 a year. The first widget runs the distant tree’s yield of about 757 kWh per kilowatt, the second the chimney’s 510; change the share used at home in either and watch the payback move.
- Import at 26.32p, the Ofgem price cap unit rate (Ofgem cap, 1 October to 31 December 2026).
- 757 kWh generated per kW a year, the article's illustrative postcode estimate rather than the site model's 850 kWh.
- Cost per kW starts at the DESNZ median installed cost per kW, 4 to 10 kW (2025/26 edition, published 28 May 2026, confirmed against the spreadsheet 2026-10-19): £1,697. The 0 to 4 kW median is £1,780.
- Year one only: no degradation, no inverter replacement, no standing charge, no battery.
Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.
- Import at 26.32p, the Ofgem price cap unit rate (Ofgem cap, 1 October to 31 December 2026).
- 510 kWh generated per kW a year, the article's illustrative postcode estimate rather than the site model's 850 kWh.
- Cost per kW starts at the DESNZ median installed cost per kW, 4 to 10 kW (2025/26 edition, published 28 May 2026, confirmed against the spreadsheet 2026-10-19): £1,697. The 0 to 4 kW median is £1,780.
- Year one only: no degradation, no inverter replacement, no standing charge, no battery.
Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.
That annual loss is the budget for everything below: the electronics that recover it, the tree work that removes it, or the honest conclusion that neither pays.
What per-panel electronics change
Two ways to break the series dependency:
Power optimisers sit behind each panel and manage its operating point individually, while one string inverter still does the conversion. A shaded panel then produces less without constraining its neighbours.
Microinverters convert at each panel, so every panel is fully independent.
Both cost more, and the choice between them is its own comparison, worked there on a shaded semi. Whether either is worth it is the budget arithmetic above: the added cost against the output recovered, across the system’s life. On an unshaded south facing roof with a factor of 1.00 there is nothing to recover. On a roof with a chimney in the middle of it, the case is usually strong.
Because the MCS method does not credit the electronics, the shade factor on the estimate is the same with or without them. An installer who says optimisers recover most of the loss should show it with modelling software run both ways, which MGD 005 itself names as the way to do it.
This is also why two quotes for the same roof can differ substantially. An installer who surveyed the shading properly may have specified optimisers; one who did not will look cheaper and generate less.
Assessing it yourself
You can do a reasonable job before any installer visits.
Identify the obstructions. Chimneys, dormers, aerials, vent pipes, trees, neighbouring buildings. Anything to the south, south-east or south-west of the array matters most, and anything within about 10 metres matters far more than its size suggests.
Think about the winter sun. This is the mistake people make. A roof inspected on a June afternoon can look clear while being shaded for much of a December day, because the sun sits far lower. The sun path chart’s lowest arc is there for exactly this reason.
Watch the roof across a day. Photograph it at three or four points from morning to evening, ideally from an upstairs window close to where the array would sit, which is where MGD 005 says to stand. That gives you a real record to hand an installer.
Use the free tools. The European Commission’s PVGIS can include terrain horizon shading in its estimate, which catches the hill or the tall treeline a site visit on a bright day glosses over. It does not see your chimney, so it is a check on far shading only.
Consider growth. A tree that clears the array now may not in five years. MIS 3002 lists reducing shade from vegetation growth among the owner’s maintenance tasks, and the monitoring habit is how you notice it happening afterwards.
What a proper survey looks like
The standard notes that an accurate estimate of shade will typically need a site visit. If the site was assessed remotely, the estimate must carry a note saying the orientation, inclination or shading were estimated, and that actual performance may be significantly lower or higher. That sentence on a quote is the cue to ask how the shading was judged without anyone standing on site.
The output should be a factor in the performance table, beside the kilowatts peak and the yield per kilowatt. Ask for it, and ask whether it was measured on site or assumed. If shading was assumed to be negligible without anyone checking, the generation figure is unreliable, and so is every savings number downstream of it.
What the quote will say
Estimated annual output: 3,400 kWh. Shade factor: 1.00.
On a roof with a chimney on the same slope, that pair is the claim to test. Ask whether the 1.00 came from a site visit or from aerial imagery, and whether any object within 10 metres was drawn as a circle on the chart. If the honest factor is 0.89, the estimate falls to about 3,026 kWh and the saving by about £72 a year; at 0.60 it falls by about £261, and the quoted payback was never the real one.
Things that are not really shading
Two commonly confused effects:
Soiling is dirt, not shadow. It reduces output slightly and mostly washes off. Bird droppings are the exception, being opaque and stubbornly attached, and on a string inverter a single opaque deposit behaves exactly like the shadow this page is about.
Cloud reduces the light reaching the whole array evenly. It lowers output without creating the mismatch that makes shading disproportionately costly, which is why weather is in every honest estimate’s yield table and your chimney is only in a surveyed one’s shade factor.
Questions people ask
How much output does a shaded panel lose?
It depends on where the shadow falls and how the panels are wired, which is why the certification method scores the whole skyline rather than one panel. MCS’s own worked example scores the same obstruction at a factor of 0.89 when it is distant and 0.60 within 10 metres. On a 4 kW array at 850 kWh per kilowatt, that is about 374 kWh lost a year in the first case and about 1,360 in the second.
Is a north side chimney a problem?
Usually not. The MCS guidance excludes objects behind the array, to the north, from the near-shade count because they cast little if any shadow on it. A chimney to the south, east or west of the panels and within 10 metres is the one to worry about, and the one a survey should draw on the chart.
Should I cut the tree down?
Price it first. If removing it lifts the factor from 0.89 to 1.00 on the worked array, it is worth about £72 a year, so tree work costing a few hundred pounds can pay for itself within the system’s life. If the tree is not yours, the answer is a conversation with its owner, not a saw, and even a tree you own is worth checking with your council for a preservation order before anyone cuts it. Trimming that lifts the skyline by a few segments on the chart is often enough.
Do optimisers fix shading?
They stop one shaded panel limiting the others, so they recover part of the string loss, not the light the shadow takes away. The MCS method gives no credit for them, so ask the installer for a modelled estimate with and without them and divide the premium by the difference, the way the comparison post does.
When to walk away
If a roof is heavily shaded for much of the day by something you cannot remove and do not own, per-panel electronics reduce the damage but do not eliminate it. MGD 005 itself says solar should not be sold where the impact of shade could be severe. You are then paying more for an installation that generates less, and the budget arithmetic above returns a number too small to justify either spend.
That is one of the genuine cases where solar is not worth it on that roof, and it is worth establishing before rather than after you have three quotes.
Check your own numbers
Take the shade factor from the performance table, multiply your kilowatts by it, and run that smaller system through the calculator: a 4 kW array at 0.89 generates like a 3.56 kW one, and at 0.60 like a 2.4 kW one. The calculator adds degradation and the inverter replacement and keeps everything in today’s money, so the payback year it gives is the verdict. A roof that fails at its real output was always going to fail, and finding out for free is the cheapest outcome shading ever produces. Start from the clear-roof case and change the size: open the calculator with the worked example loaded.
The rest of the hardware is explained under how solar panels and inverters actually work. The shade factor comes from the installer’s survey, so when you are ready for quotes, our installer directory lists Google’s listings near a postcode; check each firm’s certification on the MCS register before you rely on it.
Sources
- MCS, MIS 3002 Solar PV Systems, version 6.0 dated 18 March 2026: output as kWp times yield times shade factor, the “1 minus estimated loss” formula and the 0.89 example, the 1.00 clear-horizon rule, the site-visit and remote-assessment notes, the 90% guarantee for other methods, and vegetation in the maintenance table. Checked 2026-10-20, mcscertified.com.
- MCS, MGD 005 Solar PV Shade Evaluation Procedure, issue 1.0 dated 16 September 2020: 84 segments worth 0.01 each, the 10 metre near-shade circle, the 0.89 and 0.60 example, objects to the north excluded, the within 10% accuracy, no credit for per-panel electronics. Checked 2026-10-20, mcscertified.com.
- Department for Energy Security and Net Zero, Solar PV cost data, 2025/26 edition published 28 May 2026, median of £1,780 per kilowatt for systems up to 4 kW. Checked 2026-10-19, gov.uk.
- Ofgem, Changes to the energy price cap between 1 October and 31 December 2026: 26.32p per kWh. Checked 2026-10-20, ofgem.gov.uk.
- Octopus Energy, Smart Export Guarantee: Outgoing at 12p. Checked 2026-10-19, octopus.energy.
- European Commission, PVGIS: terrain horizon in the estimate, re.jrc.ec.europa.eu.
- gowith.solar, What the calculator models, for the 850 kWh per kilowatt figure, what the calculator models.
- The two households and the 50% share are illustrations of the MCS guidance’s own 0.89 and 0.60 example, labelled as such.
Related
- Microinverters against power optimisersBoth solve shading. They fail differently, cost differently and are serviced differently, and the shading assessment tells you whether to buy either.
- Why solar panels are not worth it: five honest casesNorth roofs, empty houses, short stays, cheap tariffs and expensive finance. The situations where the sums genuinely do not work.