Solar pool pump calculator: turnover and electricity

Compare theoretical pool turnover and pump electricity with an entered solar supply.

Your situation

Pool and circulation

Use the installed flow, preferably measured, rather than the pump's nominal maximum.

Pump electricity for the same period

An entered assumption for this period, not a solar generation forecast.

Calculated from your figures

5 hours per theoretical turnover

Turnovers in period
1.6
Pump electricity
4.8 kWh
Energy shortfall
1.8 kWh
Illustrative shortfall cost
£0.45

What this means

Based on your entered filtration flow and water volume, not a recommended operating schedule.

The working

The maths, step by step

turnover time (hours)=40÷8=5\text{turnover time (hours)} = 40 \div 8 = 5
turnovers=8×8÷40=1.6\text{turnovers} = 8 \times 8 \div 40 = 1.6
pump energy (kWh)=600×8÷1000=4.8\text{pump energy (kWh)} = 600 \times 8 \div 1000 = 4.8
energy shortfall (kWh)=max⁡(0,4.8−3)=1.8\text{energy shortfall (kWh)} = \max(0, 4.8 - 3) = 1.8
illustrative shortfall cost (£)=1.8×25÷100=0.45\text{illustrative shortfall cost (£)} = 1.8 \times 25 \div 100 = 0.45

This compares energy totals, not the timing of supply. The shortfall cost is not an electricity bill forecast.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

What turnover means

A theoretical turnover is the time needed to circulate a volume of water equal to the pool volume through the filter. Divide the pool volume by the flow through the filtration system to find the time at a constant rate.

This does not mean that every part of the pool water has been filtered once. Mixing, circulation patterns and water quality need separate attention.

Use installed flow and electrical power

Pump flow depends on the installed pipework, filter, settings and operating conditions. Use a measured flow through the filter where possible, rather than the pump's maximum advertised flow. Electrical power can also change with speed and operating conditions.

The number of turnovers in the selected period is flow multiplied by operating time, divided by pool volume. Enter the water volume in cubic metres; a cubic metre is 1,000 litres.

Compare the electricity with solar

The energy calculation multiplies pump power by the operating time. Enter the solar electricity you expect to make available to the pump in the same period to see the difference in energy totals and an illustrative cost for that difference.

Generation and demand may not coincide, so an energy total alone cannot determine actual grid imports or savings. Inverter losses, storage, variable tariffs and other household loads are excluded. Do not change filtration or sanitation schedules on the basis of this calculation; follow applicable guidance and equipment instructions.

Take it further

Solar and battery ROI calculator

See what the whole system saves.

The ROI calculator joins generation, what you use at home, export income and a battery into one payback figure, in today's prices.

Open the ROI calculator

Before you rely on this

Compare theoretical pool turnover and pump electricity with an entered solar supply.

  • Flow and pump power remain constant during the entered period; turnover is a theoretical volume comparison.
  • Solar energy is an entered amount for the same period. The calculation does not model timing, losses, storage or other household loads.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does a turnover mean every drop is filtered?

No. It is a theoretical volume comparison. Actual mixing and flow through the pool vary.

Does this tell me how long to run my pump?

No. Filtration and water quality depend on the pool, its use and equipment. Follow applicable guidance and the manufacturer's instructions.

Does the shortfall equal my grid import?

Not necessarily. The calculation compares energy over a period and does not model when solar power and pump demand coincide, storage or other loads.

Can I use the flow printed on the pump?

The installed flow can differ from a manufacturer's maximum. A flow measurement through the filter is a better input when available.