Skip to content
gowith.solar

What is your solar system performance ratio?

Use measured electricity, array capacity and irradiation on the panel plane for the same period.

Your situation

Measurements for the same period

Use irradiation on the panel plane over the same period as measured generation. The starting figure is illustrative.

Calculated from your figures

80% performance ratio

Reference generation
4,000 kWh

What this means

A comparison against nameplate output under reference irradiance, based on your same-period measurements.

How this was calculated

Based on the figures you entered.

  • Use measured AC output and plane-of-array irradiation for the same period.
  • The ratio reflects temperature, downtime, shading and measurement uncertainty as well as other losses.

Method pv-performance-ratio-v1

The working

The maths, step by step

The figures match the displayed result and are rounded for display.

performance ratio (%)=measured energyarray capacity×irradiation/reference irradiance×100\text{performance ratio (\%)} = \frac{\text{measured energy}}{\text{array capacity} \times \text{irradiation}/\text{reference irradiance}} \times 100
3200÷(4×1000/1)×100≈80%3200 \div (4 \times 1000 / 1) \times 100 \approx 80\%

Reference irradiance is 1 kW/m². Irradiation and generation cover the same period; array capacity is the DC nameplate rating.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

What the performance ratio compares

The performance ratio compares measured output with a reference based on the panels' DC nameplate rating and the sunlight received in the plane of the array. It is a way to compare output with that reference over a defined period, not a direct diagnosis of any single fault.

Use electricity generated and plane-of-array irradiation measured over the same dates. A generic annual sunshine estimate is not a substitute for a measurement on the panel plane.

Understand the reference

The reference assumes the array operates at its nameplate rating under standard test irradiance. The tool multiplies array capacity by plane-of-array irradiation to calculate the corresponding reference energy, then divides measured AC energy by it.

Temperature, shading, availability, inverter and other losses, as well as measurement uncertainty, all influence the result. A ratio above 100% can be possible under particular conditions and does not automatically mean an input is wrong.

Compare like with like

Make sure the generation and irradiation use the same interval, site and array plane. A short sunny period can behave differently from a full year, and changes in sensor calibration or system capacity can affect comparisons.

This simple calculation does not adjust for temperature or identify the cause of a low result. Investigate unexpected changes with appropriate monitoring and a qualified installer.

Take it further

Solar and battery ROI calculator

See what the whole system saves.

The ROI calculator joins generation, what you use at home, export income and a battery into one payback figure, in today's prices.

Open the ROI calculator

Before you rely on this

Use measured electricity, array capacity and irradiation on the panel plane for the same period.

  • Use measured AC output and plane-of-array irradiation for the same period.
  • The ratio reflects temperature, downtime, shading and measurement uncertainty as well as other losses.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

What is plane-of-array irradiation?

It is solar energy received per square metre on the plane of the panels over a period. Match its dates to the measured generation.

Can a performance ratio be above 100%?

Yes. Differences in operating temperature, measurements or reference conditions can produce a value above 100%. Investigate the basis before drawing conclusions.

Does performance ratio identify a fault?

No. Temperature, shade, downtime and measurement uncertainty all affect the comparison. Further investigation is needed to identify a cause.

Can I use a generic sunshine figure?

A generic estimate is not the same as measured irradiation on the array plane and may make the comparison misleading.