Skip to content
gowith.solar

Portable solar generator calculator: battery, power and refill

Compare entered load energy, battery capacity and solar refill assumptions.

Your situation

Daily energy and batteryStarting figures are illustrative. Replace them with your own measured or estimated figures.

Use the manufacturer figures for a unit you are considering.

An entered discharge and inverter efficiency assumption.

Solar refill scenario

Not daylight hours. Varies with location, season and orientation.

Power requirements

Include other loads running during startup; verify surge duration separately.

Calculated from your figures

1,111 Wh nominal battery

Daily load energy
400 Wh
Illustrative panel rating
148 W
Simultaneous running load
500 W
Load including startup
1,000 W

What this means

An entered energy scenario, not a product recommendation or electrical design.

How this was calculated

Based on the figures you entered.

  • The battery starts full and supplies the entered load without charging during autonomy.
  • Solar refill assumes no simultaneous load and a constant entered efficiency.
  • Power figures are entered loads, not a certified inverter size or compatibility check.

Method portable-solar-generator-v1

The working

The maths, step by step

Values are rounded for display. Stored energy is the battery energy needed before discharge losses.

daily load (Wh)=100×4=400\text{daily load (Wh)} = 100 \times 4 = 400
stored energy (Wh)=400×290/100≈888.89\text{stored energy (Wh)} = \frac{400 \times 2}{90/100} \approx 888.89
nominal battery (Wh)=888.8980/100≈1111.11\text{nominal battery (Wh)} = \frac{888.89}{80/100} \approx 1111.11
panel power (W)=888.894×2×(75/100)≈148.15\text{panel power (W)} = \frac{888.89}{4 \times 2 \times (75/100)} \approx 148.15

The refill calculation assumes no load during the entered refill period. Running and starting loads are shown separately: check outlet ratings, surge duration, charging limits and panel compatibility with the manufacturer.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Start with energy, then check power

A portable power station stores energy in its battery and supplies power through its outlets. Watt-hours describe energy over time; watts describe the rate at which appliances draw electricity. Both matter when comparing equipment.

Enter the average load over the hours it runs each day. For cycling loads, a measured daily total can be more useful than assuming the nameplate maximum runs continuously. The example values are editable, not recommendations.

Allow for usable capacity and losses

Multiply daily load energy by the entered days without charging. The tool divides by the assumed discharge efficiency to estimate the battery energy needed, then divides by the usable fraction to show an illustrative nominal capacity.

Manufacturers may quote usable or nominal watt-hours under different test conditions. Check whether losses are already included to avoid counting them twice. Temperature, battery age, standby consumption and changing loads can affect actual runtime.

Solar refill is a separate scenario

Equivalent full-sun hours represent solar energy in hours at a reference irradiance, not the hours between sunrise and sunset. They vary by location, season, panel angle and weather. Compare a lower-sun scenario as well as a typical day.

The panel figure estimates the rating needed to return the calculated stored energy over the entered number of days, with an entered solar efficiency. It assumes no simultaneous load while refilling and does not model cloud sequences, charge-controller limits or time of use.

Check running and starting loads

The continuous running load and the load including startup are entered separately. Compare them with the manufacturer's continuous and peak output ratings, and check how long any peak can be supplied. These figures are requirements you entered, not a certified inverter size.

Also check outlet type, panel input voltage and current, cable connections, operating temperature and safe use. A product can have enough battery energy but still be unsuitable for a particular appliance or panel. Follow the manufacturer's instructions and seek qualified advice for electrical design.

Take it further

Solar and battery ROI calculator

See what the whole system saves.

The ROI calculator joins generation, what you use at home, export income and a battery into one payback figure, in today's prices.

Open the ROI calculator

Before you rely on this

Compare entered load energy, battery capacity and solar refill assumptions.

  • The battery starts full and supplies the entered load without charging during the autonomy period.
  • Solar refill occurs over the entered days with no simultaneous load and constant assumed efficiency.
  • Running and starting loads are entered requirements, not a certified inverter size or compatibility check.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Is a watt the same as a watt-hour?

No. Watts describe power at a moment; watt-hours describe energy used over time. Both battery energy and outlet power need checking.

Do full-sun hours mean daylight hours?

No. They are equivalent hours at a reference irradiance and vary with location, season, panel angle and weather.

Does the panel estimate include using appliances while charging?

No. This refill scenario assumes the entered battery energy is replaced without a simultaneous load.

Does the result select a compatible power station?