Skip to content
gowith.solar

Greenhouse heat loss calculator: explore a steady scenario

Explore steady fabric heat loss, heater electricity and an optional solar timing scenario.

Your situation

Steady heat-loss scenario

Include the exposed surfaces represented by the entered U-value.

Illustrative. Use an appropriate area-weighted value for the surfaces.

Assumed constant; this tool considers heat loss when inside is warmer.

Illustrative. Use 1 for ideal direct electric heating or an appropriate heat-pump COP.

Optional solar electricity comparison

Calculated from your figures

4 kWh fabric heat loss

Fabric heat flow
1 kW
Electricity at entered COP
2 kWh

What this means

A steady-condition illustration for the entered surfaces only. It is not a greenhouse heating or solar-system design.

How this was calculated

Based on the figures you entered.

  • A constant U-value, area and indoor-to-outdoor temperature difference apply for the entered period.
  • Ventilation, ground losses, solar gains, thermal storage and changing weather are excluded.

Method greenhouse-heat-v1

The working

The maths, step by step

fabric heat flow (kW)=20×5×10÷1000=1\text{fabric heat flow (kW)} = 20 \times 5 \times 10 \div 1000 = 1
fabric heat (kWh)=1×4=4\text{fabric heat (kWh)} = 1 \times 4 = 4
electricity (kWh)=4÷2=2\text{electricity (kWh)} = 4 \div 2 = 2

This assumes constant conditions and excludes ventilation, ground losses, solar gains and heat storage.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

What this heat-loss scenario measures

Heat can pass through the surfaces of a greenhouse when the inside is warmer than the outside. A U-value describes the steady heat flow through a surface per unit area and temperature difference.

Enter the exposed area and an appropriate U-value for the surfaces represented. If several materials are involved, use a properly calculated area-weighted value. The example is illustrative, not a specification for a particular greenhouse.

From heat flow to energy

Multiplying U-value, area and the temperature difference gives an illustrative fabric heat flow in watts. Dividing by 1,000 converts it to kilowatts; multiplying by the entered duration gives kWh under constant conditions.

The electricity figure divides this heat by the entered coefficient of performance. A COP of 1 represents ideal direct electric heat; heat-pump performance varies with conditions.

Compare solar electricity with heating

You can enter a solar electricity amount for the same period, after other loads, and an assumed share available while heating. The comparison applies that share up to the heater electricity need. It is a scenario based on your overlap assumption, not a prediction of actual use.

Solar output and heating demand vary through the day. Matching period totals cannot establish their actual overlap, and the comparison does not model batteries, hourly power, export or other household loads.

What is missing from a greenhouse design

Real greenhouses exchange heat through ventilation, air leakage, ground contact and other paths. Sunlight, thermal storage, changing weather, humidity and controls also affect heating needs. These effects are excluded.

The calculation does not size a heater or solar array, predict overnight supply or assess plant requirements. A suitable design needs a complete heat-loss and operating assessment.

Take it further

Solar and battery ROI calculator

See what the whole system saves.

The ROI calculator joins generation, what you use at home, export income and a battery into one payback figure, in today's prices.

Open the ROI calculator

Before you rely on this

Explore steady fabric heat loss, heater electricity and an optional solar timing scenario.

  • The entered U-value and temperature difference remain constant over the entered duration.
  • Ventilation, ground losses, solar gains, thermal storage and changing weather are excluded; this is not a heating design.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does this calculate total greenhouse heating demand?

No. It illustrates heat flow through entered surfaces under constant conditions and excludes ventilation, ground losses, sunlight and thermal storage.

What is the U-value for a greenhouse?

It depends on the material and construction. Use appropriate product data and an area-weighted value when combining different surfaces.

Does this show how many solar panels heat the greenhouse?

No. The optional comparison uses your entered generation and assumed timing overlap; it does not forecast generation, model storage or size a solar system.

Why does the tool ask for a heater COP?

COP is heat delivered divided by electricity used. A value of 1 illustrates ideal direct electric heating; heat-pump COP varies with conditions.