Explore a simplified open-circuit voltage calculation for identical modules. This is not a string design.

Your situation

Identical series modules

Illustrative. Use the module datasheet value at standard test conditions.

Illustrative. Enter the signed Voc coefficient, not the power coefficient.

Illustrative. Cell temperature is not necessarily air temperature.

Calculated from your figures

Worth a closer look

424 V illustrative open-circuit voltage

At standard test temperature
400 V

What this means

This temperature illustration is not a string design or inverter compatibility check. A qualified designer must assess all relevant limits and conditions.

How this was calculated

Based on the figures you entered.

  • Identical modules have the entered open-circuit voltage and coefficient at a common cell temperature.
  • The result is an illustration, not a string design or inverter compatibility assessment.

Method string-voltage-v1

The working

The maths, step by step

reference string Voc=10×40=400 V\text{reference string Voc} = 10 \times 40 = 400\ \text{V}
illustrative Voc=400×[1+(−0.3/100)×(5−25)]≈424 V\text{illustrative Voc} = 400 \times [1 + (-0.3 / 100) \times (5 - 25)] \approx 424\ \text{V}

The linear coefficient is applied to the entered cell temperature relative to 25°C. This does not establish the design temperature or check inverter limits and other requirements.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

What open-circuit voltage means

Open-circuit voltage, often written Voc, is the voltage when a module is not supplying current. Identical modules connected in series contribute their voltages to the string.

The datasheet reference value is measured at standard test conditions, including a cell temperature of 25°C. This tool multiplies that voltage by the entered module count.

How temperature changes the illustration

A module datasheet may give a signed temperature coefficient for Voc. The calculation applies that percentage change per degree to the reference voltage. A negative coefficient generally means higher open-circuit voltage at lower cell temperatures.

Enter the Voc coefficient, not the power coefficient, and use a cell temperature rather than assuming it is identical to the air temperature. The example values are illustrations, not a design specification.

Why this is not string sizing

An electrical designer must assess the appropriate minimum site temperature, manufacturer tolerances, inverter maximum input voltage, operating voltage and current ranges, protection and the relevant installation requirements.

This calculation does not select a string length or inverter and does not check compliance or safety. Do not use the displayed voltage alone to design or change an installation.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Explore a simplified open-circuit voltage calculation for identical modules. This is not a string design.

  • Identical modules have the entered Voc and temperature coefficient at a common cell temperature.
  • This is not a string design, inverter compatibility check or electrical safety assessment.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Can this calculator choose a safe string length?

No. It illustrates voltage from entered values. A qualified designer must check temperature extremes, tolerances, inverter limits, current, protection and applicable requirements.

Why can open-circuit voltage rise in cold conditions?

For a negative Voc temperature coefficient, reducing cell temperature below the reference temperature increases the illustrated voltage.

Should I enter the panel power temperature coefficient?

No. This illustration requires the signed open-circuit voltage coefficient from the module datasheet, expressed in percent per degree Celsius.

Is the entered cell temperature the same as outdoor air temperature?

Not necessarily. Cell temperature depends on operating and environmental conditions. The tool does not determine an appropriate design temperature.