Solar string mismatch calculator: compare sampled module curves

Compare the power of two sampled module curves in series with their separate peaks.

Your situation

Common sampled current rangeEnter voltages for two modules at zero, half and all of the same current range. The starting values are examples, not measured curves.

Both curves must cover this same range under the same relevant conditions.

Module A voltages
Module B voltages

Calculated from your figures

200 W modelled series peak

Best current in range
5 A
Independent peaks in range
216.7 W
Difference
16.7 W
Difference as percentage
7.7%

What this means

Two interpolated sample curves at one condition and within the entered current range, not an annual loss or electrical design.

The working

The maths, step by step

At each sampled current, the two series voltages add. Between samples, each voltage is interpolated along a straight line.

Vseries(0)=40+40V_{\mathrm{series}}(0) = 40 + 40
Vseries(5)=30+10V_{\mathrm{series}}(5) = 30 + 10
Vseries(10)=0+0V_{\mathrm{series}}(10) = 0 + 0
Pseries(I)=I×Vseries(I),Pmax⁡≈200 W at I≈5 AP_{\mathrm{series}}(I) = I \times V_{\mathrm{series}}(I),\quad P_{\max} \approx 200\,\mathrm{W}\ \text{at}\ I \approx 5\,\mathrm{A}
difference (W)=216.66667−200=16.66667\text{difference (W)} = 216.66667 - 200 = 16.66667

On each line segment the calculator checks both endpoints and any power-curve peak inside it. The independently operated comparison uses the same sampled current range for each module.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Why a series string has a common current

Modules connected in series share the same current. Their voltages add at that current, so their combined power depends on the shape of both current-voltage curves rather than simply adding their individual maximum powers.

This tool compares two entered curves over a common current range. It is an illustration for one operating condition, not an annual energy forecast or a string design.

Enter compatible samples

Use voltage readings at zero, half and all of the same maximum current for both modules. Samples must describe comparable conditions and cover the entire entered interval. The example is invented to illustrate the method, not a measured module or a typical loss.

Voltage is assumed to fall or stay constant as current rises. Three points cannot capture all the shape or multiple peaks of a real curve; more detailed measurements and models may give a different answer.

How the comparison is calculated

The tool connects successive voltage samples with straight lines. It multiplies the resulting voltage by current, and checks each segment's endpoints and any interior power maximum. It repeats this for the sum of the two voltages and for each individual curve.

The difference compares the best series power with the sum of the two individual maxima within the sampled range. It is a power difference at one condition, not energy lost over time and not a prediction of optimizer benefit.

What the model leaves out

It does not extrapolate beyond the supplied range or model reverse bias, bypass diode activation, wiring, inverter limits, temperature changes or partial shading. A real string may have additional operating points outside the sampled range.

Do not use this result to select, wire or protect equipment. A qualified designer should use appropriate data and assess the complete electrical system.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Compare the power of two sampled module curves in series with their separate peaks.

  • Voltages are entered for the same three currents under comparable conditions and are linearly interpolated between points.
  • Comparison is restricted to the entered current range and does not model bypass diodes, reverse bias, inverter behaviour or annual energy.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does this predict annual mismatch losses?

No. It compares power for two entered curves at one condition, over a limited common current range.

Can I enter only a module's rated watts?

No. This illustration needs voltage samples at the same three currents for both modules. Rated power alone does not specify an I-V curve.

Does this simulate bypass diodes?

No. Reverse bias, bypass diode behaviour and operating points outside the entered range are excluded.

Does it tell me whether the string is safe?

No. Electrical design and safety require a qualified assessment of the complete system and relevant limits.