Skip to content
gowith.solar

Solar pool heating calculator: daily heat and cost scenario

Explore a representative day and an independent annual cost scenario.

Your situation

Representative dayStarting figures illustrate the arithmetic. Replace them with your own estimates or measurements.

An entered representative-day value, not hours of daylight.

Use an assumed whole-system efficiency for these conditions; real collector performance varies.

Enter a measured or independently estimated heat demand. The tool does not infer heat loss from pool area.

Separate annual cost scenarioThe annual fraction is your own assumption and is not inferred from the representative day.

Calculated from your figures

30 kWh illustrative daily solar heat

Collector area / pool area
50%
Matched daily heat
30 kWh
Unmatched daily demand
20 kWh
Illustrative daily share
60%
Entered annual saving scenario
£300.00
Simple payback
5 years

What this means

A representative-day energy comparison and a separate entered annual cost assumption, not a temperature or savings forecast.

How this was calculated

Based on the figures you entered.

  • Daily collector efficiency and irradiation are entered assumptions, not a forecast.
  • The daily comparison assumes available solar heat can match demand within that day.
  • The annual saving uses a separate entered annual fraction and constant costs, without inflation or discounting.

Method solar-pool-day-v1

The working

The maths, step by step

The daily heat comparison and the annual cost scenario use separate assumptions. Values are rounded for display.

collector share (%)=20÷40×100≈50\text{collector share (\%)} = 20 \div 40 \times 100 \approx 50
solar heat (kWh)=20×3×50/100=30\text{solar heat (kWh)} = 20 \times 3 \times 50 / 100 = 30
matched heat (kWh)=min⁡(30,50)=30\text{matched heat (kWh)} = \min(30, 50) = 30
unmatched demand (kWh)=50−30=20\text{unmatched demand (kWh)} = 50 - 30 = 20
day share (%)=30÷50×100≈60\text{day share (\%)} = 30 \div 50 \times 100 \approx 60
annual saving (£)=1000×30/100=300\text{annual saving (£)} = 1000 \times 30 / 100 = 300
simple payback (years)=1500÷300≈5\text{simple payback (years)} = 1500 \div 300 \approx 5

Matching assumes solar heat and demand can coincide within the day. The entered annual fraction is independent of that day's share. Simple payback assumes the same annual saving in today's money, with no maintenance, inflation or discounting.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Start with a representative day

Enter the pool's water surface area, collector area and an estimate of daily heat demand. Heat demand is not inferred from pool area: wind, humidity, air and water temperature, pool covers, ground losses and how the pool is used all matter.

An installer or independent thermal assessment can help estimate demand. The figures supplied when the page opens are examples for exploring the arithmetic, not measurements or UK averages.

Collector energy is an entered scenario

Daily irradiation on the collector plane is energy per square metre, not daylight hours. Multiply it by collector area and an assumed overall fraction delivered as useful heat. The result is a simple daily energy scenario, not an equipment performance guarantee.

Real collector efficiency changes with the temperature difference, flow, sunlight and system design. Orientation, shading, pipe losses, pumps and controls can also change output. Use independently sourced values appropriate to the system and conditions.

What the daily comparison can and cannot say

The illustrative matched heat is the smaller of the entered daily demand and estimated collector energy. This assumes available heat can be used within the day. Energy totals alone cannot show whether the pool needs heat at the same time the collector produces it.

The calculation does not simulate water temperature, weather sequences, thermal storage, backup-heater efficiency or pool safety. A zero demand has no meaningful daily percentage, and any surplus is not assumed to be saved for another day.

Annual cost and simple payback

A representative day cannot establish an annual solar fraction. Enter a separate annual proportion only if you have an appropriate seasonal estimate. The calculator multiplies that assumption by your entered annual heating cost; it does not derive it from the daily result.

Simple payback divides the entered installation cost by that illustrative annual saving. It assumes an unchanged saving in today's prices, with no maintenance costs, energy-price inflation or discounting. It is not a quote, present value or a guarantee of savings.

Take it further

Solar and battery ROI calculator

See what the whole system saves.

The ROI calculator joins generation, what you use at home, export income and a battery into one payback figure, in today's prices.

Open the ROI calculator

Before you rely on this

Explore a representative day and an independent annual cost scenario.

  • Daily demand, irradiation and collector efficiency are entered assumptions, not a weather or heat-loss forecast.
  • The daily comparison assumes estimated solar heat can match demand within that day.
  • The annual fraction is entered separately and does not come from the representative-day share.
  • Simple payback uses constant annual savings in today’s prices, without maintenance, inflation or discounting.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does the tool calculate heat loss from pool area?

No. Enter a measured or separately estimated daily heat demand. Weather, cover use and many other factors influence losses.

Is daily solar share the same as annual solar share?

No. A representative day cannot determine annual performance. The annual cost scenario uses a separate user-entered fraction.

Does this predict the pool temperature?

No. It compares entered daily energy totals and does not model timing, thermal storage or a temperature trajectory.

What does simple payback include?

It divides entered installation cost by entered annual cost multiplied by the assumed annual fraction. Maintenance, inflation and discounting are not included.