Solar fuse rating calculator: compare entered circuit figures

Compare entered current, voltage and fault figures for a candidate fuse.

Your situation

Entered current limitsIllustrative numbers only. Ask a qualified designer to establish each limit for the circuit.

Use the figure established for the actual cable and installation conditions.

Entered voltage and fault figures

Include the applicable worst-case conditions determined by the designer.

Use the rating for the relevant DC voltage and conditions.

Calculated from your figures

Entered current range overlaps

Candidate above minimum
2 A
Candidate below upper limit
2 A
DC voltage margin
100 V
Breaking capacity margin
5 kA

What this means

An arithmetic comparison of entered figures, not a fuse selection or safety check.

The working

The maths, step by step

entered upper current (A)=min⁡(15,12)=12\text{entered upper current (A)} = \min(15, 12) = 12
above minimum (A)=10−8=2\text{above minimum (A)} = 10 - 8 = 2
below upper limit (A)=12−10=2\text{below upper limit (A)} = 12 - 10 = 2
DC voltage margin (V)=1000−900=100\text{DC voltage margin (V)} = 1000 - 900 = 100
breaking margin (kA)=10−5=5\text{breaking margin (kA)} = 10 - 5 = 5

Negative margins indicate a mismatch between entered figures. Non-negative margins are not a safety certification or a fuse recommendation.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Compare the current figures

This page compares an entered candidate current rating with an entered minimum and two upper figures: the module maximum series fuse rating and the applicable cable current limit. It uses the lower upper figure in the arithmetic.

A designer must establish those figures for the specific circuit. The examples are illustrative and are not a recommendation. If the entered minimum exceeds the lower upper limit, the inputs do not describe an overlapping range.

Voltage and fault interruption are separate

A current rating alone does not specify a fuse. The device must also be suitable for the relevant DC voltage and prospective fault current under its stated conditions. This page subtracts the entered requirement from the entered rating for each quantity.

Do not substitute an AC-only rating for a DC rating or assume a breaking capacity applies at every voltage. Confirm the actual product specification and installation conditions with the designer.

Why this is not fuse selection

Temperature derating, fuse characteristics and holder, conductor installation, reverse currents, module and controller limits, system topology and applicable standards all matter. The page does not determine whether protection is required, calculate correction factors or choose a standard rating.

A non-negative margin is only a comparison of the numbers entered, not proof of compliance or safety. Use a qualified installer and the equipment documentation to design and check the complete circuit.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Compare entered current, voltage and fault figures for a candidate fuse.

  • The user supplies applicable limits and candidate ratings for the same circuit and conditions.
  • A non-negative margin is not a fuse selection, compliance determination or safety certification.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does a positive margin mean the fuse is safe?

No. The page compares entered figures and does not assess all characteristics, installation conditions or applicable standards.

Does this select a fuse or establish whether one is required?

No. A qualified designer must assess the complete circuit and select the protective device.

Why compare DC voltage and breaking capacity separately?

A current rating alone does not establish whether a device can safely interrupt the prospective fault at the relevant DC voltage.

What if the entered current range does not overlap?

The entered minimum exceeds the lower entered upper limit. The assumptions and complete circuit need professional review.