Skip to content
gowith.solar

Solar carport calculator: cost, generation and simple payback

Combine assumed carport costs, solar generation and on-site use into a simple payback scenario.

Your situation

Carport and panels

An assumption, not a panel layout or fit check.

Your cost assumptions

Example only. Replace with your own quote.

Count each item once and use a consistent VAT basis.

Annual generation and value assumptions

Replace the example with an estimate for this site and orientation.

Enter your own assumption, including any EV charging that coincides with solar.

Calculated from your figures

£7,000.00 illustrative project cost

Panels
10
Panel capacity
4 kWp
Annual generation
3,600 kWh
Assumed annual value
£540.00
Simple payback
13 years

What this means

Based on your entered costs, generation and use assumptions. This is not a quote, site assessment or the main ROI model.

The working

The maths, step by step

panels=2×5=10\text{panels} = 2 \times 5 = 10
capacity (kWp)=10×400÷1000=4\text{capacity (kWp)} = 10 \times 400 \div 1000 = 4
cost (£)=(2×1000)+(4×1000)+(1×500)+500=7000\text{cost (£)} = (2 \times 1000) + (4 \times 1000) + (1 \times 500) + 500 = 7000
annual generation (kWh)=4×900=3600\text{annual generation (kWh)} = 4 \times 900 = 3600
used on site (kWh)=3600×50÷100=1800\text{used on site (kWh)} = 3600 \times 50 \div 100 = 1800
exported (kWh)=3600−1800=1800\text{exported (kWh)} = 3600 - 1800 = 1800
annual value (£)=(1800×25+1800×5)÷100=540\text{annual value (£)} = (1800 \times 25 + 1800 \times 5) \div 100 = 540
simple payback (years)=7000÷540≈12.96296\text{simple payback (years)} = 7000 \div 540 \approx 12.96296

This simple payback holds annual values constant and excludes financing, repairs, replacements and changes in output. It is not the separate ROI calculator.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

From bays to solar capacity

Enter the number of parking bays and an assumed number of panels per bay. Multiplying by the rated panel power converts that count to a system capacity in kilowatts peak (kWp). Alternatively, estimate a panel count from an entered rectangular roof plane, panel dimensions, edge margin and gap. The tool compares two uniform orientations and uses the larger count; it does not try mixed orientations or account for obstructions.

A rectangular layout is a starting illustration, not proof the panels can be installed. Vehicle clearance, shading, drainage, foundations, access and local conditions all matter. A competent designer needs to assess the structure and electrical system before installation.

Build a cost scenario

The calculator adds the entered structure cost per bay, installed solar cost per kWp, charger cost per unit and other costs. All the initial figures are examples, not market prices. Replace them with quotations on a consistent VAT basis and avoid counting the same item twice.

Check whether foundations, connections, access, protection, permissions, ongoing maintenance and charger installation are included. This arithmetic cannot check whether a quote is complete or whether a project can be built.

Generation, use and simple payback

Annual yield is the generation per kWp for a particular site and system. Use an estimate that reflects the location, panel direction, tilt, shading and losses. The calculator multiplies it by capacity and splits the assumed generation between on-site use and export.

The on-site percentage is your assumption. An EV charger only uses solar directly when charging coincides with available generation; merely adding a charger does not establish the share. Enter applicable import and export values and check tariff terms. Annual values will vary with weather and use.

How this differs from a full ROI calculation

Simple payback divides entered project cost by an assumed annual value. It holds that value constant and excludes financing, maintenance, degradation and replacements. If annual value is zero, there is no payback to calculate.

It is a quick scenario, not the site's separate ROI model or a financial forecast. Compare assumptions and get a site-specific assessment before relying on the result.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Combine assumed carport costs, solar generation and on-site use into a simple payback scenario.

  • All costs, yield, usage shares and prices are entered examples, not market quotes or forecasts.
  • Simple payback uses a constant annual value and excludes financing, degradation, maintenance and replacements; it is separate from the ROI calculator.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Will the panels fit my carport?

You can enter panels per bay or compare two uniform grids on an entered rectangular roof plane. This simple layout excludes obstacles and mixed orientations and is not a structural or electrical assessment.

Does adding an EV charger increase the self-use percentage?

Not automatically. Enter your own self-use assumption, taking account of when the car charges and when solar generation is available.

Are the example costs market prices?

No. They are illustrative inputs and should be replaced with your own consistent quotes.

Is simple payback the same as the main ROI calculator?

No. This scenario divides cost by a constant annual value and excludes costs and physical changes that the separate ROI model considers.