Compare an entered substring voltage and diode drop at a fixed current.

Your situation

Assumed operating point

Assumed unchanged before and during the event.

Use a value for the relevant current and temperature, if known.

Calculated from your figures

125 W illustrative power difference

Diode dissipation
5 W
Difference over entered event
0.5 kWh

What this means

A fixed-current operating-point comparison, not an annual shade forecast or diode design.

The working

The maths, step by step

diode dissipation (W)=10×0.5=5\text{diode dissipation (W)} = 10 \times 0.5 = 5
power difference (W)=10×(12+0.5)=125\text{power difference (W)} = 10 \times (12 + 0.5) = 125
energy difference (kWh)=125×4÷1000=0.5\text{energy difference (kWh)} = 125 \times 4 \div 1000 = 0.5

The same current and the entered voltages are held constant. The calculation does not predict when bypass occurs or how the inverter tracks the array.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

What a bypass diode does

A bypass diode provides an alternate current path around a section of a solar module under certain mismatch conditions. When it conducts, the bypassed section contributes differently to the string voltage and the diode dissipates power.

This page is a simplified comparison at an entered operating point. It does not determine whether a diode will conduct or how many sections will be bypassed.

Compare voltages at the same current

Enter the assumed common string current, the voltage of the section before bypass, and the conducting diode's forward voltage drop. Holding current fixed, replacing the section's positive voltage contribution with a negative diode drop changes power by current times the sum of those voltages.

The diode's electrical dissipation at that point is current times its forward voltage drop. Both voltage drop and current vary with operating conditions and temperature; the defaults are invented examples.

Duration and real-world limitations

Multiplying the illustrative power difference by an entered duration gives an energy difference for that event, assuming the same operating point throughout. It is not an annual shade or production forecast.

Real module topology, cell curves, bypass switching and inverter maximum-power tracking can change the operating point. The result does not select a diode or determine its thermal, reverse-voltage or current rating. A qualified specialist must assess any repair or electrical design.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Compare an entered substring voltage and diode drop at a fixed current.

  • The same entered current applies before and during one bypass event, with constant substring voltage and diode drop.
  • The calculation does not predict bypass, annual shade losses, inverter tracking or diode ratings and is not an electrical design.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does this select a replacement diode?

No. Diode ratings, thermal conditions and module construction require an assessment by a qualified specialist.

Does this predict annual shading loss?

No. It illustrates a single assumed operating point and entered event duration, not weather or inverter tracking over a year.

Why is the diode voltage drop added to the lost substring voltage?

At the same assumed current, the comparison replaces a positive substring voltage with a negative conducting-diode voltage contribution.

Will current stay constant when bypass happens?

Not necessarily. The constant-current assumption makes the arithmetic clear but a real array and inverter can move to a different operating point.