How does cell temperature affect rated panel power?

Apply your panel power temperature coefficient to the difference from standard test conditions.

Your situation

Your panel and cell temperature

Enter the signed power coefficient from your panel datasheet.

Cell temperature is not the same as outdoor air temperature.

Not stated. The calculation treats this value as unknown.

Enter Voc from the panel datasheet to estimate open-circuit voltage.

Not stated. The calculation treats this value as unknown.

Use the signed Voc coefficient in percent per degree, not volts per degree.

Not stated. The calculation treats this value as unknown.

Enter Isc from the same panel datasheet.

Not stated. The calculation treats this value as unknown.

Use the signed Isc coefficient in percent per degree, not amps per degree.

Calculated from your figures

360 W

Open-circuit voltage
Not available
Short-circuit current
Not available

What this means

This isolates cell temperature at standard test irradiance; actual output depends on sunlight and other losses.

How this was calculated

Based on the figures you entered.

  • Cell temperature is not outdoor air temperature.
  • This isolates temperature at standard test irradiance and is not a real-time generation forecast.
  • Open-circuit voltage and short-circuit current describe separate conditions and are not multiplied to estimate maximum power.

Method panel-temperature-v2

The working

The maths, step by step

The equation uses the figures from the displayed result. Values are rounded for display.

P=PSTC(1+c(Tcell−25)100)P = P_{\mathrm{STC}} \left(1 + \frac{c(T_{\mathrm{cell}}-25)}{100}\right)
400×(1+(−0.4)×(50−25)/100)≈360 W400 \times (1 + (-0.4) \times (50-25)/100) \approx 360\ \text{W}

P is maximum power, c is the signed power coefficient in percent per degree, and T is cell temperature. The reference temperature is 25°C.

Open-circuit voltage uses its own coefficient, cV.

Voc=Voc,STC(1+cV(T−25)100)V_{oc} = V_{oc,\mathrm{STC}}\left(1 + \frac{c_V(T-25)}{100}\right)

Short-circuit current uses its own coefficient, cI.

Isc=Isc,STC(1+cI(T−25)100)I_{sc} = I_{sc,\mathrm{STC}}\left(1 + \frac{c_I(T-25)}{100}\right)

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

Why temperature changes panel power

A panel's rated power is measured at standard test conditions, including a cell temperature of 25°C. The maximum-power temperature coefficient describes the change in power for each degree away from that reference.

Enter the signed coefficient from the panel datasheet. A negative coefficient means the estimated power falls as cell temperature rises above the reference.

Cell temperature is not air temperature

Sunlight and mounting conditions can make solar cells warmer than the surrounding air. Use a measured or appropriately estimated cell temperature, rather than substituting the weather forecast without qualification.

The calculation isolates temperature while holding standard test irradiance as its reference. It does not estimate the cell temperature for you.

Interpreting the watts

The output is a comparison of panel power under a simplified condition, not a prediction of household generation. Actual sunlight, inverter behaviour, shading and system losses also matter.

Open-circuit voltage and short-circuit current have separate coefficients. If your datasheet states the reference values and coefficients in percent per degree, enter them to see each temperature adjustment.

Open circuit and short circuit are different conditions. Do not multiply these two figures to estimate maximum power, and do not use this illustration to design strings or electrical protection.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Apply your panel power temperature coefficient to the difference from standard test conditions.

  • Cell temperature is not outdoor air temperature.
  • This isolates temperature at standard test irradiance and is not a real-time generation forecast.
  • Open-circuit voltage and short-circuit current describe separate conditions and are not multiplied to estimate maximum power.

Common questions

Is cell temperature the same as outdoor temperature?

No. Solar cells can be warmer than the surrounding air. Use a measured or appropriately estimated cell temperature.

Where is the power temperature coefficient?

Look for the signed maximum-power temperature coefficient on the panel datasheet, usually expressed as percent per degree Celsius.

Why is 25 degrees Celsius used as the reference?

Standard test conditions specify a cell temperature of 25 degrees Celsius. The coefficient describes change relative to that reference.

Does this predict the electricity my system produces?

No. It isolates the temperature effect at standard test irradiance. Sunlight, inverter limits, shading and other losses also affect output.