Skip to content
gowith.solar

Solar inverter clipping energy calculator: compare power periods

Compare potential and limited AC energy across entered periods.

Your situation

Inverter assumptions

Constant in every period; actual efficiency varies.

Period 1An illustrative non-overlapping period at constant available DC power.
Period 2An illustrative non-overlapping period at constant available DC power.
Period 3An illustrative non-overlapping period at constant available DC power.

Calculated from your figures

5 kWh illustrative clipped energy

Potential AC energy
26 kWh
Limited AC energy
21 kWh
Fraction of potential energy
19.2%

What this means

For the entered periods and constant-power assumptions, not a prediction of annual loss.

The working

The maths, step by step

For each period, convert the entered DC power to potential AC power, limit it, then multiply by duration.

E1=min⁡(3×100÷100, 5)×2=6 kWhE_{1} = \min(3 \times 100 \div 100,\ 5) \times 2 = 6\,\mathrm{kWh}
E2=min⁡(6×100÷100, 5)×2=10 kWhE_{2} = \min(6 \times 100 \div 100,\ 5) \times 2 = 10\,\mathrm{kWh}
E3=min⁡(8×100÷100, 5)×1=5 kWhE_{3} = \min(8 \times 100 \div 100,\ 5) \times 1 = 5\,\mathrm{kWh}
clipped energy (kWh)=26−21=5\text{clipped energy (kWh)} = 26 - 21 = 5

This sums only the periods entered and assumes constant power in each. It does not predict weather or a full year of production.

Understand your result

A closer look at the calculation

The context behind the numbers, so you can decide what to check next.

From a power limit to energy

Clipping occurs in this illustration when potential AC power exceeds the entered inverter output limit. For each period, the calculator converts DC power using a constant efficiency, caps the result at the limit and multiplies by the period's duration.

The difference between potential and capped energy is the illustrated clipping for those periods. It is not a measurement or a prediction for a particular installation.

Use representative, non-overlapping periods

Enter power and duration for up to three non-overlapping periods. A duration of zero leaves a period out. The defaults are examples; replace them with a scenario you can explain, and include enough periods to represent the interval you want to study.

The tool assumes power is constant within each period. If you use average hourly power, brief peaks above the limit can be hidden even when the average is below it. A finer time series can produce a different estimate.

What affects a real system

Weather, orientation, temperature, shading, conversion efficiency and inverter behaviour all change power over time. Voltage limits, battery charging, curtailment and other losses are outside this simplified model.

An annual estimate requires a representative time series for the whole year and an appropriate model. This tool does not size an inverter or establish electrical compatibility.

Take it further

Solar and battery ROI calculator

You know what fits. Now see whether it pays back.

The ROI calculator takes a roof direction and system size and models generation, self-consumption, export income and replacements, all in today's prices.

Open the ROI calculator

Before you rely on this

Compare potential and limited AC energy across entered periods.

  • Each entered period has constant available DC power and the same conversion efficiency and AC limit; periods do not overlap.
  • The calculation covers only the entered periods and does not forecast weather, annual energy, battery flows or inverter compatibility.

Reference sources

Calculated results show their method version, assumptions and any data sources under "How this was calculated". Example starting figures are illustrations, not measurements.

Common questions

Does this predict annual clipping?

No. It sums only the entered periods. Annual clipping needs a representative time series and a suitable system model.

Why does duration matter?

Power is a rate; multiplying it by hours gives energy in kWh. A short peak and a sustained peak can have different energy effects.

Can hourly averages miss clipping?

Yes. Short peaks can exceed the limit even when the average power for the hour does not.

Does this choose an inverter?

No. The scenario does not check voltage, compatibility, local requirements or all operating conditions.