Try the numbersWhich ceiling sets your battery size
3,600 kWh
60%
4 kW
Demand ceiling: overnight use
5.9 kWh a day
Supply ceiling: average daily surplus
5.4 kWh a day
Binding ceiling
the array's surplus
Useful usable capacity
5.4 kWh a day
Overnight use of 5.9 kWh a day against an average daily surplus of 5.4 kWh: the array's surplus is the binding ceiling.Overnight use of 5.9 kWh a day against an average daily surplus of 5.4 kWh: the array's surplus is the binding ceiling. Values: Overnight use: kWh a day 5.9 kWh; Daily surplus: kWh a day 5.4 kWh.5.9 kWhOvernight use5.4 kWhDaily surplus
  • The binding ceiling
  • Other bars
Assumptions
  • 850 kWh per kW a year for a south facing roof (the site model's figure, not a measurement), spread evenly over 365 days.
  • Both ceilings are annual averages per day. The real surplus is several times higher on a clear summer day and close to nothing in midwinter, so a size under both ceilings fills on summer days and finds little to store in December.
  • The overnight share is yours to set; half hourly smart meter data between roughly 4pm and 8am gives the measured figure.
  • Usable capacity, not nominal: compare the result with the usable figure on a quote.

Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.

The working

The maths, step by step

daily demand ceiling=annual use×[outside-hours share (%)/100]÷365\text{daily demand ceiling} = \text{annual use} \times [\text{outside-hours share (\%)} / 100] \div 365
daily supply ceiling=max⁡(0,annual generation/365−daytime use per day)\text{daily supply ceiling} = \max(0, \text{annual generation} / 365 - \text{daytime use per day})
illustrative usable capacity=min⁡(demand ceiling,supply ceiling)\text{illustrative usable capacity} = \min(\text{demand ceiling}, \text{supply ceiling})

Understanding this calculation

Two limits on useful storage

The illustration compares average electricity used outside generating hours with average solar surplus available to charge a battery. The smaller figure is the limiting ceiling in this simplified comparison.

Enter annual consumption, the share used outside generating hours and array size. The starting values are examples, and the overnight share is yours to change.

Why daily averages can mislead

Annual generation is spread evenly across the year for this illustration. Real solar output varies with weather and season, so average surplus can overstate what is available on a winter day.

Household demand also changes. Half-hourly meter data and a site-specific generation estimate can give a better basis for an installer discussion.

Compare usable capacity and equipment

The result is usable capacity, not necessarily the nominal capacity printed on a product. Check the quoted usable figure and the warranty's operating conditions.

Power rating, efficiency, backup capability, tariff charging and equipment costs are separate considerations. This illustration does not establish the best battery or guarantee it will fill each day.

Take the next step

Put solar, battery storage and household use together in the full calculator. Its projection uses the existing calculation engine with tariff, degradation and replacement assumptions.