Not everything you put into a battery comes back out. Some is lost as heat in the conversion and in the cells themselves, on every single cycle.

The figure is modest and it is not negligible, and it matters most for the case people are usually most excited about: buying cheap electricity to use later. It is also easy to price exactly, which this page does with current published rates, worked per kilowatt hour charged in, the same way as every other battery page on this site.

What the number means

Round-trip efficiency is the proportion of energy put in that you get back out. A 90% figure, the round-trip efficiency the calculator uses, means putting in ten kilowatt hours yields nine.

The loss happens in three places:

Conversion. Alternating current to direct current on the way in, direct back to alternating on the way out. Each conversion loses a little.

The cells. Internal resistance turns some energy into heat during both charge and discharge.

Standing losses. The battery management system and any cooling draw a small continuous amount whether or not you are cycling. Most headline efficiency figures leave this out, which is why it gets its own section below.

The sum, per unit charged in

One line does all the work. A kilowatt hour charged in comes back as the efficiency’s share of a unit, worth the import rate it displaces, less whatever it cost to put in:

Gain per unit charged in = import rate x round-trip efficiency, minus the charge price.

With no losses at all, the gain would simply be the spread between the two rates. The losses take the import rate times the missing share, on every unit, whatever the charge price was. At the October to December 2026 cap of 26.32p and 90%, that is about 2.6p per unit charged in, and it comes off three very different spreads:

Charged fromCharge priceGain with no lossesGain at 90%Share lost
Intelligent Octopus Go window8p18.3pabout 15.7pabout 14%
Stored solar, Outgoing export forgone12p14.3pabout 11.7pabout 18%
An illustrative narrow spread, 14p off-peak against 24p14p10.0pabout 7.6pabout 24%

The last row uses its own 24p import rate, so its loss is 2.4p rather than 2.6p. The pattern is the point: the same few per cent of loss is a small slice of a wide spread and a large slice of a narrow one. On a narrow enough spread it is the whole margin, which is how losses can eliminate the arbitrage case entirely.

The break-even efficiency

Rearrange the sum and it gives a useful threshold: a cycle only gains anything when the efficiency is above the charge price divided by the import rate. At 8p against 26.32p that is about 30%, so no plausible battery loses money on that spread. At 14p against 24p it is about 58%, still well below any modern system, but the margin left above it is thin. At 12p export against 26.32p import it is about 46%.

A worked household: the overnight charger

A household with a 7 kWh usable battery that fills from the grid every night in the Intelligent Octopus Go window, 23:30 to 05:30, and empties into the evening: 7 kWh a day, about 2,555 kWh a year charged in.

  • At 90%, the round-trip efficiency the calculator uses and the figure Tesla publishes for the Powerwall 2 AC: each unit charged in returns about 23.7p of import and cost 8p, a gain of about 15.7p, about £401 a year
  • With no losses: 18.3p a unit, about £468 a year
  • The losses: about 256 kWh a year that never comes back out, worth about £67 at the import rate it would have displaced
  • At 87%, three points lower: about 14.9p a unit, about £381 a year, £20 less than at 90%

Notice the scale of that last line. Three points of efficiency are worth about £20 a year on a battery cycling daily from the grid. That matters when two quotes are otherwise level, and it does not rescue an expensive battery: at an illustrative £5,000 installed, the difference between 90% and 87% moves the years to recover from about 12.5 to about 13.1, before degradation.

The widget runs this household. Move the efficiency slider and watch how little the gain moves next to the price, then switch the charge source to stored solar.

Try the numbersWhat a cycled kilowatt hour earns
7 kWh
365 days
90%
£5,000
Returned per kWh charged in
23.7p
Net gain per kWh cycled
15.7p
Cycled a year
2,555 kWh
Price per usable kWh
£714
Gain a year, today's money
£401
Years to recover, no degradation
12.5 years
The same cycling gains £299 a year from stored solar and £401 a year charged off-peak.The same cycling gains £299 a year from stored solar and £401 a year charged off-peak. Values: Stored solar: Gain a year £299; Grid off-peak: Gain a year £401.£299Stored solar£401Grid off-peak
  • The charge source selected
  • Other bars
Assumptions
  • Import at 26.32p, the Ofgem price cap unit rate (Ofgem cap, 1 October to 31 December 2026).
  • Round trip efficiency of 90%, which you set; 90%, the round-trip efficiency the calculator uses, close to Tesla's stated 89% for Powerwall 3 as a whole system.
  • Stored solar gives up Octopus Outgoing export rate of 12p; grid charging pays the Intelligent Octopus Go off-peak rate, 23:30 to 05:30 of 8p (as advertised on the tariff page, checked 2026-10-20).
  • The gain is per kilowatt hour charged in, at the stated cycles on every day of the year. No degradation, no replacement: years to recover is a ceiling, not a projection.

Illustrative arithmetic on the inputs shown. For a projection with degradation, replacement and your tariff, use the calculator.

A second household: the solar store

A household with no cheap window, storing surplus solar in a 4 kWh usable battery. In the best case it fills and empties once a day, about 1,460 kWh a year charged in; a British winter will not supply that, so treat it as a ceiling.

  • At 90%: each unit gives up 12p of export and returns about 23.7p, a gain of about 11.7p, about £171 a year
  • With no losses: 14.3p a unit, about £209 a year
  • The losses: about 146 kWh a year, worth about £38

The loss per unit is the same 2.6p as on the overnight charger, because it is a share of the import rate the unit would have displaced, not of what the unit cost to put in. It is a larger share of the gain here, 18% against 14%, only because the spread is narrower: giving up 12p of export is a dearer way to fill a battery than paying 8p overnight.

AC-coupled retrofits lose more

Worth knowing if you are adding storage to an existing system.

In a DC-coupled hybrid arrangement, solar direct current charges the battery directly, with one conversion on the way out.

In an AC-coupled retrofit, solar direct current is converted to alternating current by the existing inverter, converted back to direct current to charge the battery, then converted again on discharge.

The datasheets show the size of it. Tesla’s Powerwall 2 AC states 90% measured AC to battery to AC, which starts after your solar inverter has already done its conversion; the Powerwall 3, which contains its own solar inverter, states 89% for solar to battery to home, the whole path in one figure. On the solar store above, three points of efficiency is about £12 a year (1,460 kWh times three per cent times 26.32p), which is why it is usually outweighed by the cost of discarding a working inverter. Real, and it belongs in the comparison as a number rather than a fear.

What the quoted figure includes

Ask what the number covers. Manufacturers are not consistent.

A cell-level figure looks better than a system-level one, because it excludes the inverter. The figure you care about is measured at the meter: what you drew from the wall against what you got back out into the house.

Read the footnotes too. Tesla’s Powerwall 2 AC datasheet gives its 90% “at beginning of life”, at 25°C and 3.3 kW charge and discharge power, AC to battery to AC. That is a fair and clearly stated figure, and it is also a laboratory one: a cold garage, a heavy evening load or an aged pack is not 25°C at 3.3 kW on day one. The datasheet’s own optimum operating range is 0°C to 30°C.

Ask for the system round-trip efficiency and the conditions it was measured under. If a quote gives a cell figure, treat it as optimistic and knock a few points off before it goes anywhere near your arithmetic.

What the quote will say

90% round trip efficiency for maximum savings.

Ask three things. Is it a cell figure or a system figure measured AC to AC, and does it include the solar inverter on a retrofit? Under what conditions, and at beginning of life or across the warranty? And what is the standby draw, which no round-trip figure includes? Then put a few points less, say 87%, into your own sum alongside the quoted figure: on the overnight charger the gap between them is about £20 a year, which tells you how much weight the headline deserves.

Standing consumption

The one people forget entirely.

A battery system draws a small continuous amount to run its electronics and any thermal management, and neither Tesla datasheet cited here gives a standby figure. The scale matters, so take an illustrative 30 watts: a system idling at 30 watts uses about 263 kilowatt hours a year, about £69 at the capped import rate, whether or not the battery did anything useful that day.

For a battery that cycles daily from the grid, that is a modest share of the £401 gain. For one that sits mostly idle through a dull winter without grid charging, it can be a meaningful share of everything the battery delivered that season. Ask what the standby consumption is, in watts, particularly if you expect long idle periods, and treat a blank look as a data point.

A year of losses, totalled

It helps to see the deductions as an annual bill rather than a percentage. On the overnight charger:

  1. Round-trip losses: about 256 kWh, worth about £67 of displaced import.
  2. An illustrative 30 watt standing draw: about 263 kWh, about £69.
  3. Together: about £136 a year, against a net gain of about £401 after the round-trip losses and about £332 after both.

That is not an argument against storage. It is the reason the per-cycled-unit figures on this site are net figures, and the reason a projection built on the raw spread, with no efficiency multiplication and no standby line, runs hot: on the overnight charger the raw spread gives £468 against £401 net of round-trip losses, about 17% too high, and on the solar store £209 against £171, about 22% too high, before the first winter.

Putting it in a projection

Two deductions, both belonging in any honest model:

  • Round-trip losses on every cycle, reducing what you recover, immediately and forever.
  • Degradation over the years, reducing the size of the bucket.

They are different things and both apply. A projection that includes neither is overstating what storage delivers, by more than either alone would suggest, because the smaller bucket is then also leaky. The calculator models a round-trip efficiency of 90%, close to Tesla’s stated 89% for Powerwall 3 as a whole system, and capacity that fades year on year, which is one of the reasons its battery numbers run lower than brochures’.

Questions people ask

What is a good round-trip efficiency for a home battery?

Published system figures cluster around 90%. Tesla states 90% AC to battery to AC for the Powerwall 2 AC and 89% solar to battery to home for the Powerwall 3, on their UK datasheets. The calculator uses 90%, close to both. A datasheet figure is measured under fixed laboratory conditions at beginning of life, so a cold garage or an aged pack can run a few points lower. On the overnight charger, each point is worth about £7 a year.

Does round-trip efficiency get worse as the battery ages?

The datasheets cited here state their figures at beginning of life and give none for later, so there is no published number to use. What the warranty does state is retained capacity, such as Tesla’s 80% at ten years in the UK, and the projection should carry that fade separately from the efficiency, as two deductions rather than one.

Can efficiency losses make a battery lose money?

Only on a very narrow spread. A cycle gains anything when the efficiency exceeds the charge price divided by the import rate: about 30% on 8p against 26.32p, about 46% for stored solar at 12p export, and about 58% on an illustrative 14p against 24p. A modern battery clears all three, but on the narrow spread the 7.6p left per unit may not recover the battery’s price, which is a different and more common way to lose.

Is DC coupling worth it for the efficiency alone?

Rarely. On a 4 kWh solar store cycling daily, three points of efficiency is about £12 a year, so replacing a working inverter to collect it takes decades. When the old inverter is due for replacement anyway the sum changes, which the AC against DC comparison works through.

Check your own numbers

Take the quoted system round-trip figure, knock a few points off it if it is a laboratory or cell figure, multiply by your import rate, and subtract what a charged unit costs you: the export rate you give up, or the off-peak rate you pay. That per-unit gain times the kilowatt hours you will really cycle is the battery’s year, before standby and degradation. The calculator then runs it with the fade and the replacement in it, in today’s money. Start from a 7 kWh battery on a typical solar home: open the calculator with the worked example loaded.

The other battery questions are under home battery storage: costs, sizing and whether it pays.

Sources

  • Tesla, Powerwall 2 AC datasheet (UK, dated 2020-02-27): 13.5 kWh usable, round trip efficiency 90%, “AC to battery to AC, at beginning of life”, values for 25°C and 3.3 kW charge and discharge, optimum temperature 0°C to 30°C. Checked 2026-10-20, tesla.com.
  • Tesla, Powerwall 3 datasheet (UK): 89% solar to battery to home or grid. Checked 2026-10-20, tesla.com.
  • Tesla, Powerwall warranty (European warranty region), Rev 1.16 effective 3 December 2025: 80% energy retention at ten years for the UK. Checked 2026-10-20, tesla.com.
  • Octopus Energy, Intelligent Octopus Go: 8p per kWh between 23:30 and 05:30 for the whole home, as advertised. Checked 2026-10-20, octopus.energy.
  • Octopus Energy, Smart Export Guarantee: Outgoing at 12p. Checked 2026-10-19, octopus.energy.
  • Ofgem, Changes to the energy price cap between 1 October and 31 December 2026: 26.32p per kWh. Checked 2026-10-20, ofgem.gov.uk.
  • gowith.solar, What the calculator models: round trip efficiency of 90% and year-on-year capacity fade, what the calculator models.
  • The 14p and 24p narrow spread, the 30 watt standby draw, the 7 kWh and 4 kWh batteries, the £5,000 price and the quote box are illustrations, labelled as such.